Systems Insight
Display LED and
color
Health LED
System power LED
Status
Overtemperature
(amber)
Red
Amber
The server has detected a hardware
critical temperature level.
Fan (amber)
Amber
Green
Fan has failed or is missing, but still
meets the minimum fan requirements.
Fan (amber)
Red
Green
Fan has failed or is missing and no
longer meets the minimum fan
requirements.
Power supply (amber) Red
Amber
• Only one power supply installed and
in standby mode.
• Power supply fault.
• System board fault.
Power supply (amber) Amber
Green
• Redundant power supply is installed
and only one power supply is
functional.
• AC power cord is not plugged into
redundant power supply.
• Redundant power supply fault.
• Power supply mismatch at POST or
through hot-plug addition.
Power cap (off)
—
Amber
Standby
Power cap (green)
—
Flashing green
Waiting for power.
Power cap (flashing
amber)
—
Amber
Power cap has been exceeded.
Power cap (green)
—
Green
Power is available.
IMPORTANT:
If more than one DIMM slot LED is illuminated, further troubleshooting is required. Test each bank of
DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing each DIMM in a bank with a
known working DIMM .
Component identification
85
Содержание ProLiant ML350
Страница 12: ...12 Customer self repair...
Страница 13: ...Customer self repair 13...
Страница 14: ...14 Customer self repair...
Страница 15: ...Customer self repair 15...
Страница 25: ...Illustrated parts catalog 25...
Страница 64: ...SFF configuration Two SAS Expanders 64 Removal and replacement procedures...
Страница 91: ...Rack orientation 24 LFF drives Tower orientation Component identification 91...
Страница 93: ...Rack orientation One SAS expander configuration with LFF drives Tower orientation Component identification 93...
Страница 94: ...Rack orientation Two SAS expanders configuration with SFF drives Tower orientation 94 Component identification...
Страница 106: ...Storage controller installed in slot 6 to 9 106 Cabling...
Страница 114: ...LFF configuration SAS Expander cabling One SAS Expander LFF configuration 114 SAS Expander cabling...
Страница 115: ...SFF configuration Two SAS Expanders Cabling 115...