Item
Description
Status
1
Power cap
Green = Power cap applied
Amber = Power not available
Off = Standby on not configured
2
AMP Status
Green = AMP mode enabled
Amber = Failover or invalid configuration
Off = AMP mode disabled
3
DIMM LEDs
Amber = DIMM error
Off = Normal
4
NIC LED
Solid green = Link to network
Flashing green (1 Hz/cycle per sec) = Network active
Off = No network activity
All other LEDs
Off = Normal
On = Failed
Systems Insight Display LED combinations
When the health LED on the front panel illuminates either amber or red, the server is experiencing a health
event. Combinations of illuminated SID LEDs, the system power LED, and the health LED indicate system
status.
Systems Insight
Display LED and
color
Health LED
System power LED
Status
Processor (amber)
Red
Amber
One or more of the following conditions
might exist:
• Processor in socket X has failed.
• Processor X is not installed in the
socket.
• Processor X is unsupported.
• ROM detects a failed processor
during POST.
Processor (amber)
Amber
Green
Processor in socket X is in a pre-failure
condition.
DIMM (amber)
Red
Green
One or more DIMM s have failed.
DIMM (amber)
Amber
Green
DIMM in slot X is in a pre-failure
condition.
Overtemperature
(amber)
Amber
Green
The Health Driver has detected a
cautionary temperature level.
Table Continued
84
Systems Insight Display LED combinations
Содержание ProLiant ML350
Страница 12: ...12 Customer self repair...
Страница 13: ...Customer self repair 13...
Страница 14: ...14 Customer self repair...
Страница 15: ...Customer self repair 15...
Страница 25: ...Illustrated parts catalog 25...
Страница 64: ...SFF configuration Two SAS Expanders 64 Removal and replacement procedures...
Страница 91: ...Rack orientation 24 LFF drives Tower orientation Component identification 91...
Страница 93: ...Rack orientation One SAS expander configuration with LFF drives Tower orientation Component identification 93...
Страница 94: ...Rack orientation Two SAS expanders configuration with SFF drives Tower orientation 94 Component identification...
Страница 106: ...Storage controller installed in slot 6 to 9 106 Cabling...
Страница 114: ...LFF configuration SAS Expander cabling One SAS Expander LFF configuration 114 SAS Expander cabling...
Страница 115: ...SFF configuration Two SAS Expanders Cabling 115...