Description
Chassis
Fan
configuration
Number of drives
supported by the
server
Maximum inlet
ambient temperature
NVIDIA Tesla
V100 32GB
GPU
Apollo DX2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
5 to 6 drives
Not supported
Redundant and
nonredundant
5 to 6 drives
Not supported
Redundant and
nonredundant
0 to 4 drives
Not supported
Nonredundant
0 to 3 drives
22°C (71°F)
Redundant
Not supported
Apollo DX2600
Gen10 Chassis
(24 SFF or 16 SFF
+ 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
Not supported
0 to 6 drives
Not supported
Apollo DX2800
Gen10 Chassis
(24 SFF backplane
with SAS
expander)
Redundant and
nonredundant
0 to 24 drives
Not supported
Apollo DX2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
Not supported
0 to 2 drives
22°C (71°F)
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
If the component is installed in server 1, and the server is installed in the Apollo DX2200 Gen10 Chassis, drive blanks
must be installed in drive bays 1-2 and 2-2. Similarly, if the component is installed in server 3, and the server is
installed in the AApollo DX2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and 4-2. For more
information, see
Installing drive blanks and thermal bezel blanks for components with thermal limitations
on
page 35.
If NVIDIA Tesla M10 Quad GPUs are installed in the server, and the server is installed in the Apollo DX2200 Gen10
Chassis, the maximum inlet ambient temperature can be increased by installing drive blanks in specific drive bays.
For more information, see
Installing drive blanks and thermal bezel blanks for components with thermal
If NVIDIA Tesla P4 GPUs are installed in the server, and the server is installed in the Apollo DX2200 Gen10 Chassis,
the drive blanks must be installed in specific drive bays. For more information, see
thermal bezel blanks for components with thermal limitations
on page 35.
If NVIDIA Tesla P40 GPUs are installed in the server, and the server is installed in the Apollo DX2200 Gen10
Chassis, the drive blanks must be installed in specific drive bays. For more information, see
and thermal bezel blanks for components with thermal limitations
110