Description
Chassis
Fan configuration Number of drives
supported by the server
Maximum inlet
ambient
temperature
(24 SFF or 16 SFF
+ 8 NVMe
backplane)
0 to 6 drives
With mix of SFF
and NVMe
drives:
22°C (71°F)
With SFF drives
only:
25°C (77°F)
Apollo DX2800
Gen10 Chassis
(24 SFF backplane
with SAS expander)
Redundant and
nonredundant
0 to 24 drives
Not supported
Apollo DX2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
22°C (71°F)
NVIDIA Tesla
V100 16 GB
GPU
Apollo DX2200
Gen10 Chassis
(12 LFF backplane)
Redundant and
nonredundant
5 to 6 drives
Not supported
5 to 6 drives
Not supported
0 to 4 drives
Not supported
Nonredundant
0 to 3 drives
25°C (77°F)
Redundant
22°C (71°F)
Apollo DX2600
Gen10 Chassis
(24 SFF or 16 SFF
+ 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
Not supported
0 to 6 drives
22°C (71°F)
Apollo DX2800
Gen10 Chassis
(24 SFF backplane
with SAS expander)
Redundant and
nonredundant
0 to 24 drives
Not supported
Apollo DX2800
Gen10 Chassis
(16 NVMe
backplane)
Nonredundant
0 to 8 drives
Not supported
Redundant
22°C (71°F)
Nonredundant
0 to 4 drives
22°C (71°F)
Table Continued
124
Specifications
Содержание ProLiant DX190r Gen10