18.
Close the processor retaining bracket, then secure the processor locking lever.
19.
Clean the old thermal grease from the heatsink with the alcohol swab. Allow the alcohol to evaporate
before continuing.
20.
Apply all the grease to the top of the processor in the following pattern to ensure even distribution.
21.
Install the heatsink:
a.
Position the heatsink on the processor backplate.
b.
Tighten one pair of diagonally opposite screws halfway, then tighten the other pair of screws.
c.
Finish the installation by completely tightening the screws in the same sequence.
Removal and replacement procedures