53
FGE1/0/1 000FE2-FFFE-FF0000 0 128 248 254 65535 0 Yes
FGE1/0/2 000FE2-FFFE-FF0001 0 128 248 254 65535 1 No
Table 14 Command output
Field Description
Interface
Name of a PTP interface.
Clock ID
Clock ID of the foreign master node.
C Time
class.
A Time
accuracy.
OSLV
Offset of the grandmaster clock.
SR
Hops from the grandmaster to the local clock node.
GM
Whether the node represents the grandmaster clock:
•
Yes.
•
No.
display ptp interface
Use
display ptp interface
to display PTP running information for an interface.
Syntax
display
ptp
interface
[
interface-type
interface-number
|
brief
]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
interface-type
interface-number
: Specifies an interface by its type and number. If you specify an
interface, this command displays detailed PTP running information for the specified interface. If you
do not specify an interface, this command displays PTP running information for all interfaces.
brief
: Displays brief PTP running information for all interfaces. If you do not specify this keyword, this
command displays detailed PTP running information for the specified interface or all interfaces.
Usage guidelines
If PTP is enabled on an interface, detailed running information can be displayed without the
brief
keyword in this command.
If PTP is operating on the interface, brief running information can be displayed with the
brief
keyword
in this command.
Examples
# Display brief PTP running information for all interfaces.
<Sysname> display ptp interface brief
Name State Delay mechanism Clock step Asymmetry correction
FGE1/0/1 Slave E2E Two 0
FGE1/0/2 Passive E2E Two 0