309
Default
Monitor policies do not contain any actions.
Views
CLI-defined policy view
Predefined user roles
network-admin
Parameters
number
: Specifies an action ID in the range of 0 to 231.
Usage guidelines
This command will not be executed if the device forms a single-chassis IRF fabric.
You can configure a series of actions to be executed in response to the event specified in a monitor
policy.
EAA executes the actions in ascending order of action IDs. You must make sure the execution order
is correct when you add actions to a policy.
Examples
# Configure an action for the CLI-defined policy
test
to perform an active/standby switchover.
<Sysname> system-view
[Sysname] rtm cli-policy test
[Sysname-rtm-test] action 3 switchover
action syslog
Use
action syslog
to add a Syslog action to a monitor policy.
Use
undo action
to remove an action.
Syntax
action number syslog priority level facility local-number msg msg
undo action number
Default
Monitor policies do not contain any actions.
Views
CLI-defined policy view
Predefined user roles
network-admin
Parameters
number
: Specifies an action ID in the range of 0 to 231.
priority level
: Specifies the log severity level in the range of 0 to 7. A lower value represents a higher
severity level.
facility local-number
: Specifies a logging facility by its facility number in the range of local0 to local7.
Facility numbers are used by a log host to identify log creation facilities for filtering log messages.
msg msg
: Configures the log message body.