Environmental specifications
Temperature
Operating: 5°C to 35°C (40°F to 95°F)
Nonoperating: -40°C to 60°C (-40°F to 140°F)
NOTE:
The ambient upper limit of 35°C is good up to 1524 m (5000 ft) elevation. Derate by 1°C for
every 305 m (1000 ft) above 1524 m (5000 ft). For example, at 3,048 m (10,000 ft), the upper
ambient air temperature limit is 30°C.
Humidity
Operating: 8% to 85% relative humidity, non-condensing
Nonoperating: 8% to 90% relative humidity, non-condensing
Altitude
Operating: 0 to 3,048 m (10,000 ft)
Nonoperating: 0 to 9,144 m (30,000 ft)
Shock
Operating: ½-sine: 40g, 2–3 ms (~62 cm/sec)
Nonoperating:
●
½-sine: 160 cm/s, 2–3 ms (~105g)
●
square: 422 cm/s, 20g
NOTE:
Values represent individual shock events and do not indicate repetitive shock events.
Vibration
Operating random: 0.5g (rms), 5–300 Hz, up to 0.0025 g
2
/Hz
Non-operating random: 2.0g (rms), 5–500 Hz, up to 0.0150 g
2
/Hz
NOTE:
Values do not indicate continuous vibration.
Location and ventilation
Proper ventilation for the system is important for workstation operation. To be sure that ventilation is
adequate, do the following:
●
Operate the workstation on a sturdy, level surface.
●
Provide at least:
◦
12 cm (4.7 in) clearance at the front, back, top, and bottom of the workstation
◦
16 cm (6.3 in) clearance on the right side for the optical drive
●
Confirm that the ambient air temperature surrounding the workstation falls within the specified limits
(see
Environmental specifications on page 10
).
●
Never restrict the incoming or outgoing airflow of the workstation by blocking any vents or air intakes.
10
Chapter 1 Hardware overview
Содержание Z1 G2
Страница 1: ...HP Z1 G2 Workstation Maintenance and Service Guide ...
Страница 4: ...iv About this guide ...