x109s3 172.16.3.3
Command succeeded!
5.
Remove the Management Server machine from the cluster database:
ibrix_server -d -h HOSTNAME
6.
To provide high availability for the management console, install a passive agile management
console on another file serving node. In the command, the
-F
option forces the overwrite of
the
new_lvm2_uuid
file that was installed with the X9000 Software.
/ibrix/ibrixinit -tm -C <local_cluster_interface_device> —v
<cluster_VIF_IP> -m <cluster_netmask> -d <cluster_VIF_device> -w
9009 –M passive -F
For example:
[root@x109s5 ibrix]# ./ibrixinit -tm -C bond0 -v 172.16.3.1 -m 255.255.248.0
-d bond0 -V 10.30.83.1 -N 255.255.0.0 -D bond1:0 -w 9009 -M passive -F
7.
Verify that the newly installed agile management console is in passive mode:
ibrix_fm -i
For example:
[root@x109s5 ibrix]# ibrix_fm -i
FusionServer: x109s3 (passive, quorum is running)
=============================
Command succeeded
You can now physically remove the Management Server machine from the cluster.
68
Migrating to an agile management console
Содержание StorageWorks X9320
Страница 97: ...13 When the Configure Network dialog box reappears select bond0 Configuring a file serving node manually 97 ...
Страница 108: ...Cabling diagrams Cluster network cabling diagram 108 System component and cabling diagrams ...
Страница 109: ...SATA option cabling Description Line SAS I O pathController A SAS I O pathController B Cabling diagrams 109 ...
Страница 144: ...English notice Estonian notice Finnish notice French notice 144 Regulatory compliance and safety ...
Страница 145: ...German notice Greek notice Hungarian notice Italian notice Waste Electrical and Electronic Equipment directive 145 ...
Страница 146: ...Latvian notice Lithuanian notice Polish notice Portuguese notice 146 Regulatory compliance and safety ...
Страница 147: ...Slovakian notice Slovenian notice Spanish notice Swedish notice Waste Electrical and Electronic Equipment directive 147 ...