5.
Type an Administrator password in the
New password
box.
6.
Re-type the Administrator password in the
Confirm password
box.
7.
Click the blue arrow next to the
Confirm password
box.
8.
Click
OK
.
After the Administrator password has been set, the storage system completes the recovery process.
9.
Remove the USB Flash drive from the X Series system or client PC.
Managing disks after a restoration
After a system has been restored, drive letters may be assigned to the wrong volume. Windows
Storage Server 2008 assigns drive letters after the restoration in the order of discovery. To help
maintain drive letter information, placing the drive letter into a volume label is recommended. To
change the drive letters to the appropriate one, go into Disk Management and perform the following
steps for each volume:
1.
Right-click the volume that needs to be changed.
2.
Select
Change drive Letter and Paths
.
3.
In the
Change drive Letter and Paths
dialog box, select
Change
.
4.
Select the appropriate drive letter, then click
OK
.
5.
Click
Yes
to confirm the drive letter change.
6.
Click
Yes
to continue. If the old drive letter needs to be re-used, reboot the server after clicking
Yes.
System recovery
114
Содержание StorageWorks X3000
Страница 12: ...12 ...
Страница 22: ...Installing and configuring the storage system 22 ...
Страница 40: ...Storage system component identification 40 ...
Страница 110: ...Troubleshooting servicing and maintenance 110 ...
Страница 118: ...Support and other resources 118 ...
Страница 125: ...French laser notice German laser notice Italian laser notice HP X1000 and X3000 Network Storage System User Guide 125 ...
Страница 132: ...Bulgarian recycling notice Czech recycling notice Danish recycling notice Regulatory compliance notices 132 ...
Страница 134: ...French recycling notice German recycling notice Greek recycling notice Regulatory compliance notices 134 ...
Страница 136: ...Lithuanian recycling notice Polish recycling notice Portuguese recycling notice Regulatory compliance notices 136 ...
Страница 138: ...Swedish recycling notice Battery replacement notices Dutch battery notice Regulatory compliance notices 138 ...
Страница 139: ...French battery notice German battery notice HP X1000 and X3000 Network Storage System User Guide 139 ...
Страница 140: ...Italian battery notice Japanese battery notice Regulatory compliance notices 140 ...
Страница 141: ...Spanish battery notice HP X1000 and X3000 Network Storage System User Guide 141 ...
Страница 142: ...Regulatory compliance notices 142 ...