MSL4048 — Online — The power supply is installed.
•
• MSL8048 and MSL8096 — Good — The power supply is functioning correctly.
• MSL8048 and MSL8096 — Functional, fan failure — the power supply is supplying power to
the Library, but the fan has failed so the power supply could fail soon. The power supply should
be replaced.
• Installed, failed — The power supply installed in the unit is not working and the Library no
longer has redundant power. The power supply should be replaced.
NOTE:
If the MSL4048 has two power supplies and one fails, after a power cycle the Library will not
recognize the failed power supply as installed in the Library.
The number of power supplies installed in the Library is displayed next to the icon.
• MSL8048 and MSL8096 — Removed — a power supply was installed in this location before
but has been removed. Power Supply 1 will always show
Removed
when it is missing. Power
Supply 2 will show
Removed
until the Library is rebooted.
•
Media Removal — Prevented, if the backup software is preventing media removal from the device.
When media removal is prevented, the mailslot and magazine functionality is disabled.
•
Left Magazine — Present, if the device senses the presence of the left magazine. (MSL2024)
•
Level
n
. Left Magazine — Present, if the Library senses the presence of the left magazine at level
n. The magazine levels are numbered from the bottom of the Library to the top. For example, Level
1. Left Magazine is the bottom magazine on the left side looking at the Library from the front.
(MSL4048, MSL8048, and MSL8096)
•
Right Magazine — Present, if the device senses the presence of the right magazine. (MSL2024)
•
Level
n
. Right Magazine — Present, if the Library senses the presence of the right magazine at
level n. (MSL4048, MSL8048, and MSL8096)
Viewing dynamic drive information
The
Status: Drive page (parallel SCSI)
Status: Drive page (Fibre Channel)
, and
provide detailed information about the drives present in the Library. When you click
Refresh
,
the status is updated immediately.
Figure 51 Status: Drive page (parallel SCSI)
.
Operating the Tape Library
78
Содержание StorageWorks MSL2024
Страница 16: ...16 ...
Страница 216: ...Troubleshooting 216 ...
Страница 240: ...Upgrading and servicing the Tape Library 240 ...
Страница 244: ...Support and other resources 244 ...
Страница 251: ...HP StorageWorks MSL2024 MSL4048 MSL8048 and MSL8096 Tape Libraries User and service guide 251 ...
Страница 254: ...Japanese laser notice Spanish laser notice Recycling notices English notice Regulatory compliance and safety 254 ...
Страница 256: ...Estonian notice Finnish notice French notice German notice Regulatory compliance and safety 256 ...
Страница 258: ...Lithuanian notice Polish notice Portuguese notice Romanian notice Regulatory compliance and safety 258 ...
Страница 260: ...Battery replacement notices Dutch battery notice Regulatory compliance and safety 260 ...
Страница 262: ...Italian battery notice Japanese battery notice Regulatory compliance and safety 262 ...
Страница 264: ...Regulatory compliance and safety 264 ...
Страница 266: ...Electrostatic discharge 266 ...