Running the demonstration (Support > Run Demo)
Use this option to run a device demonstration program. The demonstration continues until the
Cancel
button is pressed on the operator control panel. During the demonstration the device will move
cartridges to the tape drive and back. At the end of the demonstration the cartridges are returned to
their original slots. Access to this feature requires the administrator password.
To run the demonstration:
1.
From the Home screen, press
Previous
or
Next
until the screen displays
Support
. Press
Enter
to
select.
2.
Press
Previous
or
Next
until the screen displays
Run Demo
. Press
Enter
to select.
3.
Enter the administrator password if prompted.
4.
Use
Previous
and
Next
to select the number of cycles: 270, 540, 1080, or Endless. Press
Enter
to start the demonstration.
5.
While the test is running, the first line of the screen displays
Demo Test
. The second line displays
the number of cycles completed and the number of errors. The
Ready
LED blinks until the test is
complete.
NOTE:
To stop the demonstration, press
Cancel
on the operator control panel.
Running the slot to slot test (Support > Run Slot To Slot Test)
Use this option to show the robot's ability to move media in and out of each of the magazine slots.
Access to this feature requires the administrator password.
NOTE:
At the end of the test, the cartridges are NOT returned to their original slots.
To run the slot to slot test:
1.
From the Home screen, press
Previous
or
Next
until the screen displays
Support
. Press
Enter
to
select.
2.
Press
Previous
or
Next
until the screen displays
Run Slot To Slot Test
. Press
Enter
to select.
3.
Enter the administrator password, if prompted.
4.
Press
Previous
or
Next
until the screen displays
Select Number of Cycles.
Use
Previous
or
Next
to select the number of cycles: 270, 540, 1080, or Endless. Press
Enter
.
5.
While the test is running, the screen displays progress as shown:
Run Slot To Slot
. The second
line on the display shows the number of cycles completed. The
Ready
LED blinks until the test is
complete.
6.
When the test is complete, the screen displays the number of cycles completed and the number
of errors. If the test failed, press
Enter
to display the error and message describing the cause.
Operating the Tape Library
126
Содержание StorageWorks MSL2024
Страница 16: ...16 ...
Страница 216: ...Troubleshooting 216 ...
Страница 240: ...Upgrading and servicing the Tape Library 240 ...
Страница 244: ...Support and other resources 244 ...
Страница 251: ...HP StorageWorks MSL2024 MSL4048 MSL8048 and MSL8096 Tape Libraries User and service guide 251 ...
Страница 254: ...Japanese laser notice Spanish laser notice Recycling notices English notice Regulatory compliance and safety 254 ...
Страница 256: ...Estonian notice Finnish notice French notice German notice Regulatory compliance and safety 256 ...
Страница 258: ...Lithuanian notice Polish notice Portuguese notice Romanian notice Regulatory compliance and safety 258 ...
Страница 260: ...Battery replacement notices Dutch battery notice Regulatory compliance and safety 260 ...
Страница 262: ...Italian battery notice Japanese battery notice Regulatory compliance and safety 262 ...
Страница 264: ...Regulatory compliance and safety 264 ...
Страница 266: ...Electrostatic discharge 266 ...