![HP StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/hp/storageworks-4000-6000-8000-enterprise-virtual-arrays/storageworks-4000-6000-8000-enterprise-virtual-arrays_reference-manual_156108053.webp)
26643a
Server
with CNA
IP network
Server
with CNA
B-series
CN switch
FC attached
HP storage
Fabric A
B-series
FCoE
blade
Server
with CNA
Server
with CNA
FC attached
HP storage
FC
connections
10 GbE
Converged
10 GbE CNA
connections
Converged
10 GbE CNA
connections
FC
connections
Fabric B
B-series
CN switch
B-series
FCoE
blade
Figure 11 Converged SAN fabric with an FCoE blade
.
The convergence of Ethernet and Fibre Channel with FCoE provides the same level of connectivity as
previous technologies, but requires the following:
•
50% fewer switches in each server rack—Only two FCoE ToR switches, compared with four (two
network and two Fibre Channel) switches per rack
•
50% fewer adapters per server
•
75% fewer cable connections
•
Less power consumption
For more information about FCoE switches, see:
•
“
B-series switches and fabric rules
” on page 93
•
“
C-series Fibre Channel and FCoE switches and fabric rules
” on page 135
For more information about configuring FCoE SANs, see the
HP StorageWorks Fibre Channel Over
Ethernet Application Note
, available at
http://www.hp.com/go/sdgmanuals
.
Data availability
SAN data availability depends on the reliability of the SAN fabric, servers, and storage systems
during routine operations. The data availability level required for your SAN environment is based on:
•
Administrative requirements (for example, backup schedules, operating procedures, and staffing)
•
Protection level for applications or data
SAN Design Reference Guide
53
Содержание StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays
Страница 26: ......
Страница 34: ...SAN design overview 34 ...
Страница 60: ...SAN fabric topologies 60 ...
Страница 80: ...Fibre Channel routing 80 ...
Страница 82: ......
Страница 92: ...H series switches and fabric rules 92 ...
Страница 156: ...C series switches and fabric rules 156 ...
Страница 182: ...SAN fabric connectivity and switch interoperability rules 182 ...
Страница 184: ......
Страница 270: ...XP and VA storage system rules 270 ...
Страница 276: ...Enterprise Backup Solution 276 ...
Страница 278: ......
Страница 354: ...SAN extension 354 ...
Страница 398: ...Network Attached Storage 398 ...
Страница 400: ......
Страница 416: ...Storage security 416 ...
Страница 428: ...Best practices 428 ...
Страница 456: ...456 ...