AG mode considerations
AG mode considerations follow:
•
Ability to connect B-, C-, and M-series fabrics without interoperability constraints (see the release
notes for support information)
•
Flexible licensing option (12 or 24 ports, with a 12-port upgrade option on the 12-port model)
•
Ability to use in either switch mode or AG mode (cannot function in both modes simultaneously,
software selectable)
•
Share Fabric OS with B-series switches
•
Port failover between N_Ports (uplinks)
•
Reduces the number of cables and SFPs compared to a Pass-thru solution
•
No SAN management from the BladeSystem enclosure once the initial connections have been
configured
•
No direct storage attachment (requires at least one external Fibre Channel switch)
•
Lacks Fibre Channel embedded switch features (ISL Trunking, dynamic path selection, and extended
distances) with external links from AG to core switches
•
Managed separately from the BladeSystem, but if used with B-series switches, uses common Fabric
OS
•
Cannot move servers without impacting the SAN (Virtual Connect feature not available)
AG mode connectivity guidelines
AG-based solutions are best suited for B-series-only fabrics where you want multivendor switch
interoperability through N_Ports instead of E_Ports.
Figure 50
shows an AG with dual redundant
fabrics.
N_Ports (NPIV) (uplinks)
Blade
enclosure
with
16 servers
Se
rve
r B
ay
1
Se
rve
r B
ay
2
Se
rve
r B
ay
3
Se
rve
r B
ay
4
Se
rve
r B
ay
5
Se
rve
r B
ay
6
Se
rve
r B
ay
7
Se
rve
r B
ay
8
Se
rve
r B
ay
9
Se
rve
r B
ay
10
Se
rve
r B
ay
11
Se
rve
r B
ay
12
Se
rve
r B
ay
13
Se
rve
r B
ay
14
Se
rve
r B
ay
15
Se
rve
r B
ay
16
Access Gateway
Access Gateway
-
Blade
enclosure/
Server
management
SAN/
Storage
management
25317b
FC Fabric (B-, C-, or M-series)
(with NPIV F_Port support)
FC Fabric (B-, C-, or M-series)
(with NPIV F_Port support)
Figure 50 Access Gateway with dual redundant fabrics
.
NOTE:
The N_Ports in
Figure 50
are not host N_Ports and cannot be connected directly to storage.
Configuration highlights for
Figure 50
include:
SAN Design Reference Guide
191
Содержание StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays
Страница 26: ......
Страница 34: ...SAN design overview 34 ...
Страница 60: ...SAN fabric topologies 60 ...
Страница 80: ...Fibre Channel routing 80 ...
Страница 82: ......
Страница 92: ...H series switches and fabric rules 92 ...
Страница 156: ...C series switches and fabric rules 156 ...
Страница 182: ...SAN fabric connectivity and switch interoperability rules 182 ...
Страница 184: ......
Страница 270: ...XP and VA storage system rules 270 ...
Страница 276: ...Enterprise Backup Solution 276 ...
Страница 278: ......
Страница 354: ...SAN extension 354 ...
Страница 398: ...Network Attached Storage 398 ...
Страница 400: ......
Страница 416: ...Storage security 416 ...
Страница 428: ...Best practices 428 ...
Страница 456: ...456 ...