![HP StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays Скачать руководство пользователя страница 417](http://html.mh-extra.com/html/hp/storageworks-4000-6000-8000-enterprise-virtual-arrays/storageworks-4000-6000-8000-enterprise-virtual-arrays_reference-manual_156108417.webp)
19 Best practices
This chapter describes HP best practices for SAN design and implementation. It describes the following
topics:
• SAN planning
, page 417
• Design specification
, page 418
• SAN topology
, page 418
• SAN configuration
, page 419
• Storage-based LUN masking
, page 420
• Zoning
, page 421
• SAN scaling
, page 424
• SAN fabric merging
, page 425
For SAN design assistance, see the HP Network Storage Services website:
http://www.hp.com/hps/storage/
SAN planning
Allocate adequate time to plan your SAN prior to implementation. Design a SAN that fulfills current
and future requirements for capacity and connectivity.
During the planning phase, consider these design factors and recommendations:
•
Deployment strategy
Consider initially implementing entry-level SANs that can be interconnected to increase capacity.
Entry-level SANs are relatively easy to implement. Enterprise SANs offer economy of scale; however,
they are more complex and can take longer to implement.
•
Topology design
Choose an initial design that can accommodate expansion without transitioning to a different to-
pology.
•
Experience level
If you have limited experience implementing a SAN, start with an entry-level SAN. As you gain
experience, deploy mid-range or enterprise-level SANs.
•
SAN management strategy
Specify the policies, identification schemes, and tools to manage your SAN.
•
Technological advances
Anticipate the gradual availability of Fibre Channel switches that have more ports and faster inter-
connect speeds.
SAN Design Reference Guide
417
Содержание StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays
Страница 26: ......
Страница 34: ...SAN design overview 34 ...
Страница 60: ...SAN fabric topologies 60 ...
Страница 80: ...Fibre Channel routing 80 ...
Страница 82: ......
Страница 92: ...H series switches and fabric rules 92 ...
Страница 156: ...C series switches and fabric rules 156 ...
Страница 182: ...SAN fabric connectivity and switch interoperability rules 182 ...
Страница 184: ......
Страница 270: ...XP and VA storage system rules 270 ...
Страница 276: ...Enterprise Backup Solution 276 ...
Страница 278: ......
Страница 354: ...SAN extension 354 ...
Страница 398: ...Network Attached Storage 398 ...
Страница 400: ......
Страница 416: ...Storage security 416 ...
Страница 428: ...Best practices 428 ...
Страница 456: ...456 ...