![HP StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays Скачать руководство пользователя страница 219](http://html.mh-extra.com/html/hp/storageworks-4000-6000-8000-enterprise-virtual-arrays/storageworks-4000-6000-8000-enterprise-virtual-arrays_reference-manual_156108219.webp)
Apple Mac OS X SAN rules
This section describes the SAN rules for Apple Mac OS X.
For current storage system support, see the SPOCK website at
http://www.hp.com/storage/spock
.
You must sign up for an HP Passport to enable access.
Table 102
describes the SAN configuration rules for Apple Mac OS X.
Table 102 Apple Mac OS X SAN configuration rules
Apple Mac OS X SAN rules
Storage systems
•
Zoning is required when Mac OS X is used in a heterogeneous SAN with other
nl
operating systems.
•
Supports active/active and active/passive failover mode. A multipathing driver is embedded in the host
adapter driver.
•
Supports multipathing high-availability configuration in multiple fabrics or in a single fabric with zoned
paths.
EVA4000
EVA4100
EVA4400
EVA6000
EVA6100
EVA6400
EVA8000
EVA8100
EVA8400
EVA rules
1
•
Celerity FC-82EN, dual channel, x8 PCI Express
•
Celerity FC-84EN, quad channel, x8 PCI Express
•
XCS 6.100 or later (EVA4000/4100/6000/6100/8000/8100)
•
XCS 09000000 or later (EVA4400)
•
Command View EVA 6.0.2 or later (EVA4000/4100/6000/6100/8000/8100)
•
Command View 8.0 or later (EVA4400)
•
Command View EVA host entry operating system: Custom, custom type "00000002024000A8"
Notes:
For XCS 6.100 or later, select
Custom
from the Operating System Type list, and then enter
00000002024000A8
as the Custom type.
For XCS 09003000 or later, select
Apple Mac OS X
from the Operating System Type list.
Host adapter rules
•
Supported only with ATTO 8 Gb and 4 Gb PCIe and PCI-x host adapters:
• Celerity FC-41XS, single channel, 64-bit/133 MHz PCI-X
• Celerity FC-42XS, dual channel, 64-bit/133 MHz PCI-X
• Celerity FC-41EL, single channel, x4 PCI Express
• Celerity FC-41ES, single channel, x4 PCI Express
• Celerity FC-42ES, dual channel, x4 PCI Express
• Celerity FC-44ES, quad channel, x8 PCI Express
For more information, see
http://www.attotech.com/hp
.
Multipathing rules
•
Zoning single HA port WWPN with single EVA port WWPN is recommended.
•
Single HA port WWPN zoned with multiple EVA port WWPNs to the same EVA is supported.
•
Single HA port WWPN zoned with multiple EVAs is supported.
•
Multiple HA ports support I/O load balancing.
•
I/O load balancing can span multiple HA ports.
1
Contact an HP storage representative for the latest information on product or firmware version support.
SAN Design Reference Guide
219
Содержание StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays
Страница 26: ......
Страница 34: ...SAN design overview 34 ...
Страница 60: ...SAN fabric topologies 60 ...
Страница 80: ...Fibre Channel routing 80 ...
Страница 82: ......
Страница 92: ...H series switches and fabric rules 92 ...
Страница 156: ...C series switches and fabric rules 156 ...
Страница 182: ...SAN fabric connectivity and switch interoperability rules 182 ...
Страница 184: ......
Страница 270: ...XP and VA storage system rules 270 ...
Страница 276: ...Enterprise Backup Solution 276 ...
Страница 278: ......
Страница 354: ...SAN extension 354 ...
Страница 398: ...Network Attached Storage 398 ...
Страница 400: ......
Страница 416: ...Storage security 416 ...
Страница 428: ...Best practices 428 ...
Страница 456: ...456 ...