![HP StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays Скачать руководство пользователя страница 109](http://html.mh-extra.com/html/hp/storageworks-4000-6000-8000-enterprise-virtual-arrays/storageworks-4000-6000-8000-enterprise-virtual-arrays_reference-manual_156108109.webp)
Description
Rule
nl
number
EVA4400 Embedded Switch Module, 8 Gb Brocade—Supports connectivity to:
•
Servers
•
Storage
Note
: The EVA4400 Embedded Switch Module, 8 Gb Brocade supports the same connectivity
to HP storage systems as the 8/8, 8/24, and 8/80 switches.
•
Other B-series switches, including the EVA4400 Embedded Switch Module, 8 Gb Brocade
•
EVA and EVA4400 iSCSI Connectivity Option (see “
EVA and EVA4400 iSCSI Connectivity
Option
” on page 367)
•
HP IP Distance Gateway, B-series 400 MP Router, C-series IPS-8, 18/4, MDS 9222i, MDS
9216i (see “
HP multi-protocol long-distance products
” on page 298)
9
Access Gateway (AG) requirements are as follows:
•
AG mode for Brocade 8Gb SAN Switch for HP BladeSystem c-Class and HP StorageWorks
SAN Switch 8/8 or 8/24 (with 24 ports enabled) requires firmware 6.1
x
(or later).
•
AG mode for the SAN Switch 8/40 requires firmware 6.2
x
(or later).
•
AG mode for Brocade 4Gb SAN Switch for HP c-Class and p-Class BladeSystems requires
firmware 5.2.1b (or later).
•
AG mode for HP StorageWorks SAN Switch 4/8 or 4/16 requires firmware 5.3.0 (or later).
•
All switches that communicate with Access Gateway switches require firmware 5.1.
x
(or
later). (See “
BladeSystem with Brocade Access Gateway mode
” on page 189.)
10
In a fabric that contains a Brocade 4Gb SAN Switch for HP c-Class or p-Class BladeSystem,
StorageWorks SAN Switch 4/8, 4/16, 4/32B, 4/32, 4/64, 2/32, Core Switch 2/64, SAN
Director 2/128, or SAN Director 4/256, Core switch addressing mode is required on all other
switches in that fabric. (See “
Core switch addressing mode
” on page 127.)
11
Within a fabric, all B-series Fibre Channel switches and routers must use the HP default setting
of
iodSet
for IOD.
Note:
Brocade branded Fibre Channel switches and routers use the Brocade default setting of
iodReset
for IOD. All HP B-series Fibre Channel switches and routers must use
iodSet
.
All B-series Fibre Channel switches and routers must use the HP default setting of
dlsSet
for
non-Continuous Access configurations, and
dlsReset
for Continuous Access EVA configurations.
For XP Continuous Access, see
Table 176
on page 349.
12
Within a fabric, assign a unique domain number (domain ID) and a unique WWN to each
switch. All switch configuration parameters for the same switch models must be the same. Do
not configure any switches with a domain ID of 8, which is reserved for HP-UX.
Insistent Domain ID mode is required on all B-series switches in fabrics that include HP-UX 11i
v3 (or earlier) or IBM AIX servers, when configuring switches for FICON or when implementing
port-based fabric zoning.
Routing policy—HP recommends the same routing policy be used in all switches within a fabric.
13
Switch data routing policies—Different switch models support different routing policies. For most
configurations, the default routing policy provides the best performance. See "Routing Traffic"
in the appropriate Fabric OS administrator guide.
14
StorageWorks SAN Switch Integrated 32 or 64 and HP SureStore FC Switch 6164 support a
maximum of four chassis per fabric. Each chassis adds six switches to the fabric switch count.
The maximum fabric configuration is four chassis with ten additional SAN switches.
15
SAN Design Reference Guide
109
Содержание StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays
Страница 26: ......
Страница 34: ...SAN design overview 34 ...
Страница 60: ...SAN fabric topologies 60 ...
Страница 80: ...Fibre Channel routing 80 ...
Страница 82: ......
Страница 92: ...H series switches and fabric rules 92 ...
Страница 156: ...C series switches and fabric rules 156 ...
Страница 182: ...SAN fabric connectivity and switch interoperability rules 182 ...
Страница 184: ......
Страница 270: ...XP and VA storage system rules 270 ...
Страница 276: ...Enterprise Backup Solution 276 ...
Страница 278: ......
Страница 354: ...SAN extension 354 ...
Страница 398: ...Network Attached Storage 398 ...
Страница 400: ......
Страница 416: ...Storage security 416 ...
Страница 428: ...Best practices 428 ...
Страница 456: ...456 ...