NOTE:
HP does not recommend the ring fabric for applications requiring many-to-many connectivity.
25093a
Figure 5 Ring fabric
.
If the ring fabric has fewer than 12 switches, you can add switches (called satellite switches) outside
the ring to create more user ports (
Figure 6
). M-series switches have a 3-hop maximum, reducing the
total number of switches that can be configured in a ring to 7; satellite switches are not supported.
NOTE:
Adding satellite switches slightly reduces fabric availability.
For more information on switch fabric maximums, see:
•
“
H-series switches and fabric rules
” on page 83
•
“
B-series switches and fabric rules
” on page 93
•
“
C-series Fibre Channel and FCoE switches and fabric rules
” on page 135
•
“
M-series switches and fabric rules
” on page 157
SAN Design Reference Guide
41
Содержание StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays
Страница 26: ......
Страница 34: ...SAN design overview 34 ...
Страница 60: ...SAN fabric topologies 60 ...
Страница 80: ...Fibre Channel routing 80 ...
Страница 82: ......
Страница 92: ...H series switches and fabric rules 92 ...
Страница 156: ...C series switches and fabric rules 156 ...
Страница 182: ...SAN fabric connectivity and switch interoperability rules 182 ...
Страница 184: ......
Страница 270: ...XP and VA storage system rules 270 ...
Страница 276: ...Enterprise Backup Solution 276 ...
Страница 278: ......
Страница 354: ...SAN extension 354 ...
Страница 398: ...Network Attached Storage 398 ...
Страница 400: ......
Страница 416: ...Storage security 416 ...
Страница 428: ...Best practices 428 ...
Страница 456: ...456 ...