Troubleshooting
Table 5-2: Is the System Power LED Off?
continued
Answer Possible
Reasons Possible
Solutions
No
If the system power button LED is amber, press the Power
On/Standby button.
Refer to Table 5-3.
Note: For LED locations and functions, refer to Chapter 4, “Server Component Identification.”
Table 5-3: Is the System Power LED Green?
Answer Possible
Reasons Possible
Solutions
Power On/Standby button has not been pressed
firmly.
Firmly press the power button.
A power supply problem exists. The power
supply may not be connected or inserted
properly, it may have a damaged connector, or it
may have failed.
Be sure that the power supply is undamaged, the
power supply is fully seated, and the power supply
LED is green.
The system may have experienced a short.
Check for bent connector pins and improperly seated
expansion boards.
The front panel LED assembly has failed.
Be sure that the front panel LED assembly cable is
connected to the power backplane.
No, it is
off
If these solutions do not solve the problem, contact
an authorized service provider for assistance.
Yes
If the system power button LED is green, refer to
Table 5-4.
Note: For LED locations and functions, refer to Chapter 4, “Server Component Identification.”
Table 5-4: Is the External Health LED Green?
Answer Possible
Reasons Possible
Solutions
No, it is amber
One power supply has failed;
therefore, power supply
redundancy is lost.
Be sure that each installed power supply is securely connected
to an AC power source.
Locate the amber power supply LED to identify the failed power
supply.
Contact an authorized service provider for replacement parts
and service.
No, it is red
All installed power supplies
have experienced a failure.
Remove all AC power from power supplies and reconnect to
clear the error condition.
Replace the power supply. Contact an authorized service
provider for replacement parts and service.
Yes
Refer to Table 5-5 if the external health LED is green.
Note: For LED locations and functions, refer to Chapter 4, “Server Component Identification.”
HP ProLiant DL585 Server Maintenance and Service Guide
5-5
Содержание ProLiant DL585