![HP ProLiant DL585 Скачать руководство пользователя страница 58](http://html.mh-extra.com/html/hp/proliant-dl585/proliant-dl585_maintenance-and-service-manual_163365058.webp)
Removal and Replacement Procedures
Rear Fan Cage
To remove the rear fan cage:
1. Power down the server. Refer to “Powering Down the Server” ea rlier in this chapter.
2. Extend the server from the rack. Refer to “Extending the Server from the Rack” earlier in
this chapter.
3. Remove the access panel. Refer to “R emoving the Access Panel” earlier in this chapter.
4. Remove the processor memory boards. Refer to “Proce ssor Memory Boards” earli er in
this chapter.
NOTE: It is not necessary to remove the fans prior to removing the fan cage. The fan cage can be
removed with the fans installed.
5. Loosen the two thumbscrews that secure the rear fan cage to the chassis (1).
6. Remove the rear fan cage from the chassis (2).
Figure 2-32: Removing the rear fan cage
Reverse the steps to replace the rear fan cage.