Removal and Replacement Procedures
System Battery
WARNING: This server contains an internal lithium manganese dioxide or vanadium
pentoxide battery. A risk of fire and burns exists if the battery is not handled properly.
To reduce the risk of personal injury:
•
Do not attempt to recharge the battery.
•
Do not expose to temperatures higher than 60
°
C (140
°
F).
•
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire
or water.
•
Replace only with the HP spare designated for this server.
CAUTION: Do not dispose of batteries, battery packs, and accumulators with the
general household waste. To forward them to recycling or proper disposal, use the
public collection system or return them to either HP or an authorized service provider.
To remove the battery:
1. Power down the server. Refer to “Powering Down the Server” ea rlier in this chapter.
2. Extend the server from the rack. Refer to “Extending the Server from the Rack” earlier in
this chapter.
3. Remove the access panel. Refer to “R emoving the Access Panel” earlier in this chapter.
4. Locate the battery on the system board.
NOTE: It may be necessary to remove some PCI-X expansion boards to gain access to the battery.
Figure 2-35: Locating the battery on the system board
HP ProLiant DL585 Server Maintenance and Service Guide
2-41