Troubleshooting
Table 5-5: Is the Internal Health LED Green?
Answer Possible
Reasons Possible
Solutions
For component failure identification (amber LED), check the hood label.
No, it is amber
A processor is in pre-failure condition.
A DIMM is in pre-failure condition.
One memory bank is valid, but another bank
is missing a DIMM.
One memory bank is valid, but another bank
has mismatched DIMMs installed.
One memory bank is valid, but another bank
has an unsupported DIMM type installed.
A redundant fan has failed.
Use internal component failure LEDs to identify:
•
Missing components
•
Degraded components
•
Failed components
•
Improperly installed components
Replace any missing components, reseat all
components, and restart the system.
If LED failure indicator reappears, replace the
failing component. For more troubleshooting
information, refer to the HP Servers
Troubleshooting Guide.
For component replacement procedures, refer to
the HP ProLiant DL585 Servers Maintenance and
Service Guide at
www.hp.com/support
Contact an authorized service provider for
replacement parts and service.
No, it is red
A processor has failed.
Processor 1 is not installed.
A processor is an unsupported type.
Processor does not have an associated
PPM installed.
A PPM has failed.
A DIMM has experienced a multibit error.
DIMM pairs have mismatched DIMMs.
DIMMs are missing.
DIMMs are an unsupported type.
A required fan has failed.
A thermal event has occurred.
Use internal component failure LEDs to identify:
•
Missing components
•
Failed components
•
Improperly installed components
•
Thermal event
Replace any missing components, reseat all
components, and restart the system.
If LED failure indicator reappears, replace the
failing component. For more troubleshooting
information, refer to the HP Servers
Troubleshooting Guide.
For component replacement procedures, refer to
the HP ProLiant DL585 Servers Maintenance and
Service Guide at
www.hp.com/support
Contact an authorized service provider for
replacement parts and service.
A component is not properly seated.
Check the interlock LEDs on top of the front
access panel. Be sure that all components are
seated securely.
continued