Server Component Identification
QuickFind Diagnostic Display
Figure 4-6: QuickFind Diagnostic Display LEDs
Table 4-6: QuickFind Diagnostic Display LEDs
Item Description
Status
Action
1 Fan
Off
=
normal
On = attention required
Be sure fan is installed and seated properly.
If fan is installed and seated properly, replace the fan.
2 Processor
Off
=
normal
On = attention required
Processor pre-failure notification. Inspect the IML logs
and/or POST messages. Processor may need to be
replaced.
3 Processor
memory
board
Off = normal
On = attention required
Processor memory board power failure. If problem
persists, replace processor/memory board.
4 Processor
power
module
Off = normal
On = attention required
PPM power failure. If problem persists, replace PPM.
If the PPM and the BRD LEDs are both on, there is a
configuration error.
continued
HP ProLiant DL585 Server Maintenance and Service Guide