Component identification 87
FBDIMM slots
FBDIMM slots are numbered sequentially (1 through 8) and the paired banks are identified by the letters
A, B, C, and D.
Systems Insight Display LEDs and internal health LED
combinations
When the internal health LED on the front panel illuminates either amber or red, the server is experiencing
a health event. Combinations of illuminated system LEDs and the internal health LED indicate system
status.
Systems Insight Display
LED and color
Internal health
LED color
Status
Processor failure, socket X
(amber)
Red
One or more of the following conditions may exist:
•
Processor in socket X has failed.
•
Processor X is not installed in the socket.
•
Processor X is unsupported.
•
ROM detects a failed processor during POST
Amber
Processor in socket X is in a pre-failure condition.
PPM failure, slot X (amber)
Red
One or more of the following conditions may exist:
•
PPM in slot X has failed.
•
PPM is not installed in slot X, but the corresponding
processor is installed.
FBDIMM failure, slot X
(amber)
Red
FBDIMM in slot X has failed.
Amber
FBDIMM in slot X is in a pre-failure condition.
FBDIMM failure, all slots in
one bank (amber)
Red
One or more FBDIMMs has failed. Test each bank of
FBDIMMs by removing all other FBDIMMs. Isolate the
failed FBDIMM by replacing each FBDIMM in a bank with
a known working FBDIMM.
Содержание ProLiant DL380 G5 DPSS
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 16: ...Customer self repair 16 ...
Страница 48: ...Removal and replacement procedures 48 4 Open the heatsink retaining bracket 5 Remove the heatsink ...
Страница 72: ...Removal and replacement procedures 72 14 Install the power supplies 15 Power up the server ...
Страница 74: ...Cabling 74 Fan board cabling Hard drive backplane power cabling ...
Страница 76: ...Cabling 76 Systems Insight Display cabling ...
Страница 94: ...Component identification 94 Only the 12 fan configuration supports all connectors ...