Removal and replacement procedures 69
1.
During the server startup sequence, press the
F9
key to access RBSU.
2.
Select the
System Options
menu.
3.
Select
Serial Number
. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the system
during the manufacturing process and should NOT be modified. This option
should only be used by qualified service personnel. This value should
always match the serial number sticker located on the chassis.
4.
Press the
Enter
key to clear the warning.
5.
Enter the serial number and press the
Enter
key.
6.
Select
Product ID
.
7.
Enter the product ID and press the
Enter
key.
8.
Press the
Esc
key to close the menu.
9.
Press the
Esc
key to exit RBSU.
10.
Press the
F10
key to confirm exiting RBSU. The server will automatically reboot.
I/O fan bracket
These procedures apply to both the 6- and 12-fan configurations. If necessary, configuration-specific
illustrations are provided.
To remove the component:
1.
Power down the server (on page
30
).
2.
Remove all power supplies ("
Hot-plug power supply
" on page
34
).
3.
Extend or remove the server from the rack ("
Remove the server from the rack
" on page
31
).
4.
Remove the access panel ("
Access panel
" on page
32
).
5.
Remove the power supply cage assembly ("
Power supply cage assembly
" on page
41
).
CAUTION:
To prevent damage to the server or expansion boards, power down the server
and remove all AC power cords before removing or installing the PCI riser cage.
6.
Remove the PCI riser cage ("
PCI riser cage
" on page
62
).
IMPORTANT:
For this procedure, you do not need to remove the hot-plug fans from the
processor fan bracket. When reinstalling the processor fan bracket, press the top of each fan
to be sure it seats securely.
7.
Remove the processor fan bracket ("
Processor fan bracket
" on page
39
).
8.
Remove the hot-plug fans from the I/O fan bracket ("
Hot-plug fan
" on page
38
).
9.
Remove the battery pack ("
Removing the battery pack
" on page
54
).
10.
Remove the air baffle ("
Air baffle
" on page
55
).
11.
Remove all FBDIMMs ("
FBDIMMs
" on page
56
).
12.
Remove the PPMs ("
PPM
" on page
45
).
13.
Remove the system board ("
System board
" on page
67
).
14.
Remove the I/O fan bracket.
Содержание ProLiant DL380 G5 DPSS
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 16: ...Customer self repair 16 ...
Страница 48: ...Removal and replacement procedures 48 4 Open the heatsink retaining bracket 5 Remove the heatsink ...
Страница 72: ...Removal and replacement procedures 72 14 Install the power supplies 15 Power up the server ...
Страница 74: ...Cabling 74 Fan board cabling Hard drive backplane power cabling ...
Страница 76: ...Cabling 76 Systems Insight Display cabling ...
Страница 94: ...Component identification 94 Only the 12 fan configuration supports all connectors ...