Component identification 88
Systems Insight Display
LED and color
Internal health
LED color
Status
FBDIMM failure, all slots in
all banks (amber)
Red
One or more FBDIMMs has failed. Test each bank of
FBDIMMs by removing all other FBDIMMs. Isolate the
failed FBDIMM by replacing each FBDIMM in a bank with
a known working FBDIMM.
Online spare memory
(amber)
Amber
Bank X failed over to the online spare memory bank.
Online spare memory
(flashing amber)
Red
Invalid online spare memory configuration.
Online spare memory
(green)
Green
Online spare memory enabled and not failed.
Mirrored memory (amber)
Amber
Bank(s) X failed over to the mirrored memory bank(s).
Mirrored memory (flashing
amber)
Red
Invalid mirrored memory configuration.
Mirrored memory (green)
Green
Mirrored memory enabled and not failed.
Overtemperature (amber)
Amber
The Health Driver has detected a cautionary temperature
level.
Red
The server has detected a hardware critical temperature
level.
Riser interlock (amber)
Red
PCI riser cage is not seated.
Fan (amber)
Amber
One fan is failed or removed.
Red
Two or more fans have failed or are removed.
SAS device numbers
Содержание ProLiant DL380 G5 DPSS
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 16: ...Customer self repair 16 ...
Страница 48: ...Removal and replacement procedures 48 4 Open the heatsink retaining bracket 5 Remove the heatsink ...
Страница 72: ...Removal and replacement procedures 72 14 Install the power supplies 15 Power up the server ...
Страница 74: ...Cabling 74 Fan board cabling Hard drive backplane power cabling ...
Страница 76: ...Cabling 76 Systems Insight Display cabling ...
Страница 94: ...Component identification 94 Only the 12 fan configuration supports all connectors ...