Removal and replacement procedures 32
NOTE:
To access some components, you may need to remove the cable management arm.
To access the product rear panel components, open the cable management arm:
1.
Power down the server (on page
30
).
2.
Swing open the cable management arm.
3.
Remove the cables from the cable trough.
4.
Remove the cable management arm.
Access panel
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
Do not operate the server for long periods with the access panel open or
removed. Operating the server in this manner results in improper airflow and improper
cooling that can lead to thermal damage.
To remove the component:
1.
Power down the server if performing a non-hot-plug installation or maintenance procedure ("
Power
down the server
" on page
30
).
2.
Extend the server from the rack (on page
29
).
3.
Use the T-15 Torx screwdriver attached to the rear of the server to loosen the security screw on the
hood latch.
4.
Lift up on the hood latch handle and remove the access panel.
To replace the component, reverse the removal procedure.
SAS hard drive blank
Содержание ProLiant DL380 G5 DPSS
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 16: ...Customer self repair 16 ...
Страница 48: ...Removal and replacement procedures 48 4 Open the heatsink retaining bracket 5 Remove the heatsink ...
Страница 72: ...Removal and replacement procedures 72 14 Install the power supplies 15 Power up the server ...
Страница 74: ...Cabling 74 Fan board cabling Hard drive backplane power cabling ...
Страница 76: ...Cabling 76 Systems Insight Display cabling ...
Страница 94: ...Component identification 94 Only the 12 fan configuration supports all connectors ...