About this task
Follow the steps below to replace one of these drives:
• DL360/380G9 300GB 10K SAS 2.5" HDD
• DL360/380G9 300GB 15K SAS 2.5" HDD
• DL360/380G9 600GB 10K SAS 2.5" HDD
• DL360/380G9 900GB 10K SAS 2.5" HDD
• DL360/380G9 1.2TB 10K SAS 2.5" HDD
• DL360/380G9 200GB SATA 2.5" SSD
Procedure
1. Remove the drive.
a. Push button to release locking latch. (#1 in the following image)
b. Pull on unlocked latch to remove HDD/SSD. (#2 in the following image)
Drives are hot-swappable so power down of server is not recommended. However, only one
drive must be replaced at a time until RAID array rebuild is complete.
2. Replace the drive.
a. Insert HDD/SSD into empty drive slot.
b. Secure HDD/SSD by closing the latch.
c. Refer to the Hard Drive LED table for the drive rebuild status.
d. Check using Avaya application tools for RAID status if available.