External Maintenance Field Replaceable Units
Note:
HDD Field Replaceable Units (FRUs) are Hot Swappable assuming you have RAID 1
configuration with 2 HDDs, and 1 of the HDDs is in working order. A RAID 5 Configuration is
hot-swappable only if you are swapping 1 HDD, and the other 2 through 7 HDDs are in working
order.
Description
Hot-swappable?
DL360/380G9 300GB 10K SAS 2.5" HDD
Y
DL360/380G9 300GB 15K SAS 2.5" HDD
Y
DL360/380G9 600GB 10K SAS 2.5" HDD
Y
DL360/380G9 900GB 10K SAS 2.5" HDD
Y
DL360/380G9 1.2TB 10K SAS 2.5" HDD
Y
DL360/380G9 200GB SATA 2.5" SSD
Y, if redundant
DL360/380G9 500 WAC PWR SUP
Y, if redundant
DL360/380G9 800 WAC PWR SUP
Y, if redundant
DL360/380G9 800 WDC PWR SUP
Y, if redundant
Related links
Power supply problems
on page 18
Hard disk drive problems
Hard drive LEDs
Use these indicators to identify status and problems with a hard drive.
Maintaining and Troubleshooting the HP ProLiant DL360 G9 Server
November 2015
Maintaining and Troubleshooting the HP ProLiant DL360 G9 Server
14
Comments on this document? [email protected]