Event, Error, and Warning Messages
EFI Error and Warning Messages
Appendix A
114
SEL and FPL Log Entries
This section is a quick reference for the intelligent platform management interface (IPMI) events recorded in
the SEL and FPL files. These logs are available via the management processor (MP) card interface or the
BMC command line interface (CLI).
•
All entries from the SEL are forwarded to the FPL. The FPL is a circular log so the newest entries replace
the oldest. The FPL contains forward progress messages from the BMC, System firmware, EFI, and the
OS.
•
The SEL will not accept new entries once it is full and contains only those events considered of major
importance to system operation.
•
Both contain type 02 and E0 messages.
•
A triplet is formed from the SensorType, EventType, and the lower nibble of the Data1 fields of Type 02
events. MP firmware displays the triplet in the Keyword field.
NOTE
Systems with firmware version 2.0 or higher also have a
clearlogs
command that will clear
out the log files should they become full.
Accessing the logs with BMC CLI commands
The
cli>sl -f
command displays the forward progress log. For example:
Rec#
Sev Generator/Sensor Description
Event ID
Data, Timestamp
-------- - ---------------- ------------ ----------- --------------------------
53
Error building SMBIOS
Contact the HP Support center for
assistance.
54
Failure constructing the EFI Memory Data
Table (MDT)
Contact the HP Support center for
assistance.
55
Universal Unique IDentifier (UUID) error
Update with sysset command.
56
Error reading CPU SMBIOS information ROM
Reboot the server. If the error message is
repeated, replace the failing processor.
57
Error accessing Field Replaceable Unit (FRU)
information
Replace the FRU which was reported. If
the error message is repeated, contact the
HP Support center for assistance.
58
Checksum error accessing FRU information
Replace the FRU which was reported. If
the error message is repeated, contact the
HP Support center for assistance.
59
FRU information version error
Replace the FRU which was reported. If
the error message is repeated, contact the
HP Support center for assistance.
Table A-1
EFI Error and Warning Messages (Continued)