Table A-1
EFI Error and Warning Messages
Error
Number
Error/Warning Message
Solution
2
Insufficient resources to assign to one or more
I/O devices
Incorrect I/O configuration. Contact the
HP Support center for assistance.
4
Unexpected hardware I/O configuration
Incorrect I/O configuration. Contact the
HP Support center for assistance.
7
No Baseboard Management Controller (BMC)
installed in platform
Ensure the BMC ROM is installed; update
BMC firmware
8
BMC cannot be accessed
Check system logs for errors. Replace the
base unit.
9
One or more BMC ports failed
Communication with the BMC failed.
Check power. Replace the base unit.
10
BMC system event log is full
Clear SEL
11
Platform SCR is bad
Contact the HP Support center for
assistance.
12
Set time to BMC SEL failed
Communication with the BMC failed.
Replace the base unit.
13
SEL get info failed
Communication with the BMC failed.
Replace the base unit.
14
Initial BMC SEL event failed
Communication with the BMC failed.
Replace the base unit.
15
Update of BMC buffered data failed
Communication with the BMC failed.
Replace the base unit.
16
All Advanced Configuration and Power
Interface (ACPI) BMC ports bad
Communication with the BMC failed.
Replace the base unit.