Chapter 5
Troubleshooting
Identifying and Diagnosing Hardware Problems
91
Warnings
The following tables provide additional information about each specific warning associated with the various
possible LED lighting sequences when the system LED is yellow.
Red
Red
BMC
Red
Red
Temperature
Red
Red
Power Supply
Red
Red
Red
Red
Unknown
a. This LED can display any color other than red (for example,
green or off).
Table 5-5
Unknown Warning
System
LED
LED 1
LED 2
LED 3
LED 4
Problem
Solution
Flashing
Yellow
Red
Red
Red
Red
Unknown
warning.
View the SEL
cli>sl e
for
additional information. For
further assistance, contact your
HP Support Engineer.
Table 5-6
Memory Warnings
System
LED
LED 1
LED 2
LED 3
LED 4
Problem
Solution
Flashing
Yellow
Red
Green
Off
Off
Mismatched
memory
pairs.
View the SEL for additional
information. Review the
information on installing
memory in “Installing and
Configuring” in the
hp Integrity
rx1620 Maintenance Guide
.
Flashing
Yellow
Red
Off
Green
Green
Memory
thermal load
order.
View the SEL for additional
information.
Flashing
Yellow
Red
Green
Green
Green
Bad serial
presence
detect (SPD)
information
(can't detect
type).
View the SEL for additional
information. For further
assistance, contact your HP
Support Engineer.
Table 5-4
Diagnostic LEDs Fault and Warning Categories (Continued)
LED 1
LED 2
LED 3
LED 4
Category