To power on the server blade to full power when the server blade is inserted in the enclosure:
1.
From the MP Main Menu, enter
pr
to access the Power Restore Configuration menu.
2.
Enter
on
to set the power restore configuration to power on to full power, as shown below:
3.
Enter
y
to confirm changing the power restore configuration setting.
4.
Power on the server through the iLO 2 MP by accessing the Power Control menu.
Access the Power Control menu by entering
pc
from the MP Main Menu.
5.
Enter
on
to power on the server blade as shown below:
6.
Enter
y
to confirm changing the power control setting.
The server blade is now set to power on to full power when it is inserted into the enclosure.
Configuring Remote Access to the Server Blade
At this point in the iLO 2 MP configuration process, you must decide if the server blade will be
accessed remotely. Remote access allows the server blade to be stopped, started, and configured,
and allows troubleshooting, from a remote location. If you disable remote access, you must configure
and troubleshoot the server blade through the SUV cable serial port.
Depending on your set up, see one of the following procedures:
•
Remote access allowed. See
“Remote Access Allowed” (page 51)
.
•
Remote access not allowed. See
“Remote Access Not Allowed ” (page 52)
.
50
Installing the Server Blade Into the Enclosure