7 System Cabling
For comprehensive cabling instructions for the 3PAR StoreServ 8000 Storage system, see the
HPE 3PAR StoreServ 8000 Storage Series Cabling Configuration Guide
:
http://www.hpe.com/info/storage/docs
Cabling Controller Nodes—4-Node systems
Interconnect link cables are used with 4-node systems to interconnect the nodes.
NOTE:
•
2-node system
—Interconnect link ports are not used and the port LEDs should always be
off.
•
4-node systems
—Interconnect link ports are used to connect nodes together.
Controller nodes are numbered 0 to 3 from bottom to top. Connections between controller nodes
0 and 1 and controller nodes 2 and 3 use four large interconnect link cables.
These cables are directional and must be installed correctly for the system to function properly.
When inserting the cables, you should hear a click to confirm the cable is correctly installed. If
you have to force the connector, the connector is upside down and needs to be inverted. The
direction of the cable connection is indicated by labels on either end of the cable.
In
, see label
A
for interconnecting controller node 0 or 1. See label
C
for
interconnecting controller node 2 or 3.
Figure 79 Interconnect controller nodes
Cabling Controller Nodes—4-Node systems
79
Содержание HPE 3PAR StoreServ 8000
Страница 52: ...3 Install the cage nuts Figure 50 Cage nut installation 52 Power Distribution Unit Installation ...
Страница 53: ...4 Install the PDU Figure 51 1U PDU installation Figure 52 0U PDU installation Installing 1U and 0U PDUs 53 ...
Страница 117: ...Battery for 764 W PCM 764 W PCM without Battery 580 W PCM 3 5 inch LFF Drive 2 5 inch SFF Drive System Components 117 ...
Страница 132: ...Workaround Close the browser and relaunch the Service Processor IP Setup wizard 132 Troubleshooting ...
Страница 142: ...142 Warranty and regulatory information ...
Страница 143: ...Regulatory Information 143 ...