Power Cooling Modules
The power cooling module (PCM) is an integrated power supply and cooling fan.
There are two types of PCMs:
•
580 W (gold series) PCM
—Used in the drive enclosures.
•
764 W (gold series) PCM
—Used in the controller node enclosures and includes a replaceable
battery.
The PCMs are located at the rear of the system and on the sides of the enclosure. There are
two PCMs per enclosure. The PCMs are numbered 0 and 1 from left to right. In the LFF 3.5-inch
drive enclosure, the two PCMs are located diagonally from one another and the remaining PCM
slots are filled with blank panels (see
CAUTION:
Do not proceed without first correcting all fault indications (except for PCM batteries).
NOTE:
The batteries are fully charged during shipment. The batteries might lose some charge
and show a degraded status immediately when power is applied. This is a temporary condition.
Proceed with the system initialization process and software installation. Check the LEDs again
when the installation is complete.
The cluster is not formed until the HPE 3PAR OS software configuration has been performed.
34
Identifying System Components and Numbering
Содержание HPE 3PAR StoreServ 8000
Страница 52: ...3 Install the cage nuts Figure 50 Cage nut installation 52 Power Distribution Unit Installation ...
Страница 53: ...4 Install the PDU Figure 51 1U PDU installation Figure 52 0U PDU installation Installing 1U and 0U PDUs 53 ...
Страница 117: ...Battery for 764 W PCM 764 W PCM without Battery 580 W PCM 3 5 inch LFF Drive 2 5 inch SFF Drive System Components 117 ...
Страница 132: ...Workaround Close the browser and relaunch the Service Processor IP Setup wizard 132 Troubleshooting ...
Страница 142: ...142 Warranty and regulatory information ...
Страница 143: ...Regulatory Information 143 ...