NOTE:
The middle support bracket is only used in a Hewlett Packard Enterprise rack with
posts that extend to a depth of 29 inches. Install the middle support bracket when transporting
the system to another location. Retain and store the middle support brackets if they are not being
used. Installing the middle support bracket can be difficult due to limited clearance in the vertical
rails of the rack.
Install the middle support bracket before transporting:
1.
Align the middle support bracket holes with the top holes of the rails. The orientation of the
middle support bracket is neutral.
2.
Insert and tighten screws.
Figure 58 Middle support bracket installation
NOTE:
Two kinds of T25 Torx screws are provided. The shoulder screws that fasten the rail
channels to the inside of the rack are longer and have flat (not rounded) screwheads (see
“Installing a 2U Rail Shelf” (page 61)
or
“Installing a 4U Rail Shelf” (page 61)
).
The shorter screws with rounded screwheads are for the middle support bracket.
60
System Component Installation in Existing Rack
Содержание HPE 3PAR StoreServ 8000
Страница 52: ...3 Install the cage nuts Figure 50 Cage nut installation 52 Power Distribution Unit Installation ...
Страница 53: ...4 Install the PDU Figure 51 1U PDU installation Figure 52 0U PDU installation Installing 1U and 0U PDUs 53 ...
Страница 117: ...Battery for 764 W PCM 764 W PCM without Battery 580 W PCM 3 5 inch LFF Drive 2 5 inch SFF Drive System Components 117 ...
Страница 132: ...Workaround Close the browser and relaunch the Service Processor IP Setup wizard 132 Troubleshooting ...
Страница 142: ...142 Warranty and regulatory information ...
Страница 143: ...Regulatory Information 143 ...