Configuring
iLO
35
ProLiant BL p-Class Standard Configuration Parameters
Beginning IP Address (Bay 1)—Assigns the starting IP address. All IP
addresses must be valid addresses.
Ending IP Address (Bay 16)—Assigns the ending IP address. All IP addresses
must be valid addresses.
Subnet Mask—Assigns the subnet mask for the default gateway. This field may
be filled in if either Static IP Bay Configuration or DHCP is enabled. The entire
IP address range must conform to the subnet mask.
Gateway IP Address—Assigns the IP address of the network router that
connects the Remote Insight subnet to another subnet where the management PC
resides. This field may be filled in if either Static IP Bay Configuration or DHCP
is enabled.
ProLiant BL p-Class Advanced Configuration Parameters
Domain Name—Enables you to assign the name of the domain in which the iLO
will participate.
Primary DNS Server—Assigns a unique DNS server IP address on your
network.
Secondary DNS Server—Assigns a unique DNS server IP address on your
network.
Tertiary DNS Server—Assigns a unique DNS server IP address on your
network.
Primary WINS Server—Assigns a unique WINS server IP address on your
network.
Secondary WINS Server—Assigns a unique WINS server IP address on your
network.
Содержание HP Integrated Lights-Out
Страница 1: ...HP Integrated Lights Out User Guide July 2004 Sixth Edition Part Number 238882 006 ...
Страница 20: ......
Страница 134: ......
Страница 142: ......
Страница 166: ...166 User Guide Integrated Lights Out Time Restrictions IP Network Address Restrictions IP Mask IP Range DNS Name ...
Страница 169: ...Directory Services 169 To remove any of the entries highlight the entry in the display list and click Remove ...
Страница 192: ......
Страница 222: ......
Страница 232: ...232 User Guide Integrated Lights Out ...
Страница 240: ......
Страница 268: ......
Страница 362: ......
Страница 398: ...398 User Guide Integrated Lights Out Third party hardware or software Operating system type and revision level ...
Страница 406: ......