Remote Insight Command Language
313
MOD_BLADE_RACK Runtime Errors
The possible MOD_BLADE_RACK error messages include:
•
•
•
•
•
Rack information is open for read-only access. Write access is required for
this operation.
Rack Name too long.
Enclosure Name too long.
Bay Name too long.
User does not have correct privilege for action. CONFIG_ILO_PRIV
required.
GET_DIAGPORT_SETTINGS
The GET_DIAGPORT_SETTINGS command requests the respective iLO
diagnostic port settings. For this command to parse correctly, the
GET_DIAGPORT_SETTINGS command must appear within a RACK_INFO
command block, and RACK_INFO MODE can be set to read or write.
Example:
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<RACK_INFO MODE="read">
<GET_DIAGPORT_SETTINGS/>
</RACK_INFO>
</LOGIN>
</RIBCL>
GET_DIAGPORT_SETTINGS Parameters
None
GET_DIAGPORT_SETTINGS Runtime Errors
None
Содержание HP Integrated Lights-Out
Страница 1: ...HP Integrated Lights Out User Guide July 2004 Sixth Edition Part Number 238882 006 ...
Страница 20: ......
Страница 134: ......
Страница 142: ......
Страница 166: ...166 User Guide Integrated Lights Out Time Restrictions IP Network Address Restrictions IP Mask IP Range DNS Name ...
Страница 169: ...Directory Services 169 To remove any of the entries highlight the entry in the display list and click Remove ...
Страница 192: ......
Страница 222: ......
Страница 232: ...232 User Guide Integrated Lights Out ...
Страница 240: ......
Страница 268: ......
Страница 362: ......
Страница 398: ...398 User Guide Integrated Lights Out Third party hardware or software Operating system type and revision level ...
Страница 406: ......