![HP ESG-D Series Скачать руководство пользователя страница 311](http://html.mh-extra.com/html/hp/esg-d-series/esg-d-series_user-manual_160473311.webp)
5-175
Hardkey and Softkey Reference
Mode - GSM
In this example:
•
GSM On
- Indicates that GSM is enabled. This field changes to
GSM Off
when
GSM Off On
is set to
Off
.
•
Data Format: Framed
- Indicates that the data pattern is a framed transmission.
This field changes to
Data Format: Pattern
when the
Data Format Pattern Framed
softkey is set to
Pattern
indicating that
you are
transmitting a continuous stream of your selected data pattern
.
•
Modulation: GMSK
- Indicates that GMSK modulation is being internally
generated.
•
GSM: STANDARD
- Indicates that the structure of the GSM transmission follows the
standard as defined by the GSM protocol. This field changes to
GSM: MODIFIED
under the following circumstances:
•
filter
bandwidth-multiplied-by-bit-time (BbT)
is changed
•
bit rate is changed
•
burst shape is changed
•
phase polarity is set to invert
•
differential encoding is turned off
•
Diff Encode: On
- Indicates that differential encoding is turned on.
•
Bit/Symbol: 1
- Indicates that 1 bit per symbol is required according to the GSM
standard.
•
Bit Rate: 270.833kbps
- The bit rate is set according to the GSM standard. This
can be changed in the Bit Rate menu. A * next to the value indicates that it differs from
the standard.
•
Filter: 0.30 Gaussian
- Indicates that the Gaussian filter is used with a BbT
of 0.30. This can be changed in the Filter menu. A * next to the BbT value indicates that
it differs from the standard.
•
Data: PN9
- Indicates that a PN9 sequence has been selected for transmitting without
framing. In this example, the text in this field is grey, indicating an inactive function
(framed mode is on). Other selections allowed include PN15, fixed 4-bit patterns, fixed
patterns of ones and zeroes, user files, or external data.
•
Repeat: Cont
- Indicates that the data pattern repeat is set to continuous mode. If
you select single mode, this field changes to
Repeat: Single
.
•
Phase Pol: Normal
- Indicates the direction of rotation of the phase modulation
vector. If you select inverted mode, this field changes to
Phase Pol: Invert
.
•
Ref Freq: 10Mhz
- Indicates the timebase reference frequency is 10 MHz. This
field changes to 13 MHz if external 13 MHz is on.
Содержание ESG-D Series
Страница 4: ...ii ...
Страница 34: ...Contents 30 ...
Страница 46: ...1 12 Preparing for Use Verifying Signal Generator Operation ...
Страница 138: ...5 2 Hardkey and Softkey Reference ...
Страница 164: ...5 28 Hardkey and Softkey Reference Amplitude ...
Страница 166: ...5 30 Hardkey and Softkey Reference Arrow Keys ...
Страница 168: ...5 32 Hardkey and Softkey Reference Display Contrast Keys ...
Страница 188: ...5 52 Hardkey and Softkey Reference FM ...
Страница 196: ...5 60 Hardkey and Softkey Reference Frequency ...
Страница 198: ...5 62 Hardkey and Softkey Reference Help ...
Страница 200: ...5 64 Hardkey and Softkey Reference Hold ...
Страница 202: ...5 66 Hardkey and Softkey Reference Incr Set ...
Страница 236: ...5 100 Hardkey and Softkey Reference LF Out ...
Страница 238: ...5 102 Hardkey and Softkey Reference Local ...
Страница 240: ...5 104 Hardkey and Softkey Reference Mod On Off ...
Страница 242: ...5 106 Hardkey and Softkey Reference Mode ...
Страница 336: ...5 200 Hardkey and Softkey Reference Mode GSM ...
Страница 422: ...5 286 Hardkey and Softkey Reference Mode PDC ...
Страница 466: ...5 330 Hardkey and Softkey Reference Mode PHS ...
Страница 532: ...5 396 Hardkey and Softkey Reference Numeric Keypad ...
Страница 554: ...5 418 Hardkey and Softkey Reference Power Switch ...
Страница 564: ...5 428 Hardkey and Softkey Reference Preset ...
Страница 570: ...5 434 Hardkey and Softkey Reference Pulse ...
Страница 574: ...5 438 Hardkey and Softkey Reference Recall ...
Страница 576: ...5 440 Hardkey and Softkey Reference Return ...
Страница 578: ...5 442 Hardkey and Softkey Reference RF On Off ...
Страница 584: ...5 448 Hardkey and Softkey Reference Save ...
Страница 604: ...5 468 Hardkey and Softkey Reference Sweep List ...
Страница 666: ...7 20 Operation Userfile Applications ...
Страница 675: ...8 9 Safety and Regulatory Declaration of Conformity Declaration of Conformity ...