that it is displayed in proportion to its capacity (allocated storage size), or so that all the application
areas and shared folders are displayed at the same size.
1.
In the Actions pane, click
Configure Display Options
.
The
Display Options
dialog box opens.
2.
Click the
Scaling
tab.
3.
Select the storage-display proportion setting:
• According to capacity, using automatic scaling—Displays logical disks and volumes, and
application areas according to relative size, but leaves the display readable.
• All as the same size—Displays logical disks and volumes, and application areas as the same
size.
4.
Click
Apply
to apply your change.
5.
Click
OK
.
Configure Application Credentials
Use the
Application Credentials
dialog box to set or update user name and password security
credentials applicable to the All-in-One Storage System.
1.
Expand the nodes of the tree in order to view the credential status of an application server.
2.
If the
Credential Status
column reads
OK
or
Not required
, no action is required for that application.
3.
If the
Credential Status
column reads
Failed
or
Not set
, select the application row and then click
Update Credentials
. An
Enter Credentials
dialog box is displayed.
4.
Type the user name and password of a user with sufficient privileges as described in the dialog
and then click
OK
.
5.
Repeat steps 1 through 4 for each application server.
Configure Storage Networks
Use the
Storage Networks
dialog box to configure a preferred private storage network for iSCSI traffic
between your All-in-One Storage System and any connected servers that use the iSCSI protocol. This
dialog box appears the first time you use the Host an Exchange Storage Group wizard, Host a SQL
Server Database wizard, or Host a User-Defined Application wizard. Settings configured in this dialog
box affect only iSCSI traffic.
HP strongly recommends configuring all iSCSI-based storage for application servers on a dedicated
Ethernet subnet. The purpose of a private LAN for iSCSI traffic is to is to guarantee dedicated network
bandwidth for storage as well as increased security.
To configure storage networks for iSCSI traffic:
1.
Under
Preferred Storage Network
, select a network that will be designated to manage all iSCSI
traffic.
2.
Under
Available for Failover
, select a network that can be used to manage iSCSI traffic in the
event that the preferred storage network fails. In the event of iSCSI initiator failure, iSCSI traffic
fails over to the designated network.
HP StorageWorks All-in-One Storage System
65
Содержание AK373A - StorageWorks All-in-One Storage System 1200r 5.4TB SAS Model NAS Server
Страница 1: ...HP StorageWorks All in One Storage System user guide Part number 440583 006 First edition June 2008 ...
Страница 14: ...14 ...
Страница 34: ...Installing and configuring the server 34 ...
Страница 48: ...Storage system components 48 ...
Страница 56: ...Storage management overview 56 ...
Страница 96: ...Managing data protection 96 ...
Страница 100: ...Managing storage 100 ...
Страница 134: ...System recovery 134 ...
Страница 184: ...Microsoft Services for Network File System MSNFS 184 ...
Страница 198: ...BSMI notice Japanese notice Korean notice A B Class A equipment Class B equipment Regulatory compliance and safety 198 ...
Страница 216: ...Index 216 ...