Chapter 4
Cabling and Power Up
Setting Up the Customer Engineer Tool (PC)
52
If the CE Tool is a laptop using Reflection 1, ensure communications settings are in place, using the following
procedure:
1. From the Reflection 1 Main screen, pull down the
Connection
menu and select
Connection Setup
.
•
Select
Serial Port
.
•
Select
Com1
•
Check the settings and change, if required.
Go to
More Settings
to set Xon/Xoff. Click
OK
to close the More Settings window.
•
Click
OK
to close the Connection Setup window.
2. Pull down the
Setup
menu and select
Terminal
(under the
Emulation
tab).
•
Select terminal type VT100 or VT102
•
Click
Apply
.
This option is not highlighted if the terminal type you want is already selected.
3. Click
OK
.
Connecting the CE Tool to the Local RS232 Port on the MP
This connection allows direct communications with the MP.
Only one window can be created
on the CE
Tool to monitor the MP. When enabled, it provides direct access to the MP and any partition.
Use the following procedure to connect the CE Tool to the Local RS-232 Port on the MP:
1. Connect one end of a null modem cable (9-pin to 9-pin) (Part Number 5182-4794) to the M cable connector
labeled CONSOLE.
2. Connect the other end of the RS-232 cable to the CE Tool.
Содержание 9000 rp7420
Страница 4: ...Contents iv Index 67 ...
Страница 6: ...Tables vi ...
Страница 8: ...Figures viii ...
Страница 74: ...Chapter 4 Cabling and Power Up Using the Checklist 66 ...