5-49
Hardkey/Softkey Reference
Analyzer Functions
draws a quarter-page plot in the lower right quadrant of
the page.
draws a quarter-page plot in the upper right quadrant of
the page.
resets the seconds counter to zero in real-time clock.
presents the S-parameter menu, which is used to define
the input ports and test set direction for S-parameter
measurements.
provides a measurement calibration for reflection-only
measurements of one-port devices or properly terminated
two-port devices, at port 1 of an S-parameter test set or
the reflection test port of a transmission/reflection test set.
is used to enter the standard numbers for the first class
required for an S
11
1-port calibration. (For default cal kits,
this is the open.)
is used to enter the standard numbers for the second class
required for an S
11
1-port calibration. (For default cal kits,
this is the short.)
is used to enter the standard numbers for the third class
required for an S
11
1-port calibration. (For default kits,
this is the load.)
measures the short circuit TRL/LRM calibration data for
PORT 1.
provides an S11 and S21 enhanced response calibration
(forward direction). Enhanced response generates a 1-port
cal for S11 and an improved calibration over the response
cal for S21 (ES only).
provides a measurement calibration for reflection-only
measurements of one-port devices or properly terminated
two-port devices, at port 2 of an S-parameter test set or
the transmission test port of a transmission/reflection test
set.
provides an S22 and S12 enhanced response calibration
(reverse direction). Enhanced response generates a 1-port
cal for S22 and an improved calibration over the response
cal for S12. (ES only)
is used to enter the standard numbers for the first class
required for an S
22
1-port calibration. (For default cal kits,
this is the open.)
RIGHT LOWER
RIGHT UPPER
ROUND SECONDS
S PARAMETERS
S11 1-PORT
S11A
S11B
S11C
S11 REFL SHORT
S11/21 ENH. RESP
S22 1-PORT
S22/12 ENH. RESP
S22A
Содержание 8719ES
Страница 6: ...vi ...
Страница 10: ...Contents x Contents ...
Страница 11: ...1 1 1 HP 8719 20 22ES Specifications and Characteristics ...
Страница 60: ...1 50 HP 8719 20 22ES Specifications and Characteristics Instrument Specifications ...
Страница 61: ...2 1 2 HP 8719 20 22ET Specifications and Characteristics ...
Страница 98: ...2 38 HP 8719 20 22ET Specifications and Characteristics Instrument Specifications ...
Страница 99: ...3 1 3 Front Rear Panel ...
Страница 111: ...4 1 4 Menu Maps ...
Страница 113: ...4 3 Menu Maps Menu Maps Figure 4 2 Menu Map for Copy ...
Страница 114: ...4 4 Menu Maps Menu Maps Figure 4 3 Menu Map for Display ...
Страница 115: ...4 5 Menu Maps Menu Maps Figure 4 4 Menu Map for Format Figure 4 5 Menu Map for Local ...
Страница 116: ...4 6 Menu Maps Menu Maps Figure 4 6 Menu Map for Marker Marker Fctn and Marker Search ...
Страница 118: ...4 8 Menu Maps Menu Maps Figure 4 9 Menu Map for Power and Sweep Setup ET only ...
Страница 119: ...4 9 Menu Maps Menu Maps Figure 4 10 Menu Map for Power and Sweep Setup ES only ...
Страница 120: ...4 10 Menu Maps Menu Maps Figure 4 11 Menu Map for Preset ...
Страница 121: ...4 11 Menu Maps Menu Maps Figure 4 12 Menu Map for Save Recall ...
Страница 122: ...4 12 Menu Maps Menu Maps Figure 4 13 Menu Map for Scale Ref ...
Страница 128: ...5 1 5 Hardkey Softkey Reference ...
Страница 194: ...6 1 6 Error Messages ...
Страница 222: ...7 1 7 Options and Accessories ...
Страница 234: ...8 1 8 Preset State and Memory Allocation ...
Страница 253: ...8 20 Preset State and Memory Allocation Memory Allocation ...
Страница 254: ...9 1 9 Understanding the CITIfile Data Format ...
Страница 269: ...9 16 Understanding the CITIfile Data Format Useful Calculations ...
Страница 270: ...10 1 10 Determining System Measurement Uncertainties ...
Страница 281: ...10 12 Determining System Measurement Uncertainties Measurement Uncertainty Equations ...