5-63
Hardkey/Softkey Reference
Analyzer Functions
sets the upper limit value for the start of the segment. If a
lower limit is specified, an upper limit must also be
defined. If no upper limit is required for a particular
measurement, force the upper limit value out of range (for
e500 dB).
When
or
is pressed, all
the segments in the table are displayed in terms of upper
and lower limits, even if they were defined as delta limits
and middle value.
If you attempt to set an upper limit that is lower than the
lower limit, or vice versa, both limits will be automatically
set to the same value.
(Option 010 only) remembers a specified window pulse
width (or step rise time) different from the standard
window values. A window is activated only for viewing a
time domain response, and does not affect a displayed
frequency domain response.
lets you control the analyzer with the computer over
HP-IB as with the talker/listener mode, and also allows
the analyzer to become a controller in order to plot, print,
or directly access an external disk. During this peripheral
operation, the host computer is free to perform other
internal tasks that do not require use of the bus (the bus is
tied up by the network analyzer during this time).
The pass control mode requires that the external
controller is programmed to respond to a request for
control and to issue a take control command. When the
peripheral operation is complete, the analyzer passes
control back to the computer. Refer to the HP-IB
programming chapters in the programmer's guide for
more information.
In general, use the talker/listener mode for programming
the analyzer unless direct peripheral access is required.
selects the A or B power sensor calibration factor list for
use in power meter calibration measurements.
is used to select the preset condition defined by the user.
is used to define kits other than those offered by
Hewlett-Packard.
UPPER LIMIT
UPPER LIMIT
LOWER LIMIT
USE MEMORY ON off
USE PASS CONTROL
USE SENSOR A/B
USER
USER KIT
Содержание 8719ES
Страница 6: ...vi ...
Страница 10: ...Contents x Contents ...
Страница 11: ...1 1 1 HP 8719 20 22ES Specifications and Characteristics ...
Страница 60: ...1 50 HP 8719 20 22ES Specifications and Characteristics Instrument Specifications ...
Страница 61: ...2 1 2 HP 8719 20 22ET Specifications and Characteristics ...
Страница 98: ...2 38 HP 8719 20 22ET Specifications and Characteristics Instrument Specifications ...
Страница 99: ...3 1 3 Front Rear Panel ...
Страница 111: ...4 1 4 Menu Maps ...
Страница 113: ...4 3 Menu Maps Menu Maps Figure 4 2 Menu Map for Copy ...
Страница 114: ...4 4 Menu Maps Menu Maps Figure 4 3 Menu Map for Display ...
Страница 115: ...4 5 Menu Maps Menu Maps Figure 4 4 Menu Map for Format Figure 4 5 Menu Map for Local ...
Страница 116: ...4 6 Menu Maps Menu Maps Figure 4 6 Menu Map for Marker Marker Fctn and Marker Search ...
Страница 118: ...4 8 Menu Maps Menu Maps Figure 4 9 Menu Map for Power and Sweep Setup ET only ...
Страница 119: ...4 9 Menu Maps Menu Maps Figure 4 10 Menu Map for Power and Sweep Setup ES only ...
Страница 120: ...4 10 Menu Maps Menu Maps Figure 4 11 Menu Map for Preset ...
Страница 121: ...4 11 Menu Maps Menu Maps Figure 4 12 Menu Map for Save Recall ...
Страница 122: ...4 12 Menu Maps Menu Maps Figure 4 13 Menu Map for Scale Ref ...
Страница 128: ...5 1 5 Hardkey Softkey Reference ...
Страница 194: ...6 1 6 Error Messages ...
Страница 222: ...7 1 7 Options and Accessories ...
Страница 234: ...8 1 8 Preset State and Memory Allocation ...
Страница 253: ...8 20 Preset State and Memory Allocation Memory Allocation ...
Страница 254: ...9 1 9 Understanding the CITIfile Data Format ...
Страница 269: ...9 16 Understanding the CITIfile Data Format Useful Calculations ...
Страница 270: ...10 1 10 Determining System Measurement Uncertainties ...
Страница 281: ...10 12 Determining System Measurement Uncertainties Measurement Uncertainty Equations ...