Setting Global System Parameters
How to Set the Characteristics of the External Input
90
HP 81200 Data Generator/Analyzer Platform User Guide, Revision 2.1
How to Set the Characteristics of
the External Input
The EXT INPUT connector of the master clock module can be used to start
and stop the system.
1
Open the Parameter Editor for the master clock module (see
Start the Parameter Editor for Global Parameters” on page 85
The Clock Reference window appears.
2
Click the
External Input
tab.
The External Input window shows the alternatives:
Figure 29
External Input Configuration Window
3
Choose the desired start/stop mode. Options are:
–
Immediate
:
The timing system is started either manually by the user with a mouse
click or by a software command.
–
Gated
:
The timing system is armed by pressing the Run icon. The user
interface displays HALTED as long as the system is not started. The
timing system is started or stopped according to the chosen polarity.
The system is stopped, when the sequence terminates. The user
interface displays RUNNING, HALTED, or STOPPED. See also
Содержание 81200
Страница 1: ...Revision 2 1 HP 8 1 200 D a t a G e n e r a t o r A n a l y z e r P l a t f o r m User Guide ...
Страница 9: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 9 What s New in This Release ...
Страница 15: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 15 Introduction to the System ...
Страница 49: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 49 Test Development Overview ...
Страница 57: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 57 Structure of the User Interface ...
Страница 83: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 83 Setting Global System Parameters ...
Страница 93: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 93 Connecting the DUT ...
Страница 105: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 105 Setting Up Ports and Channels ...
Страница 127: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 127 Choosing the Kind of Measurement ...
Страница 155: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 155 Creating and Editing Segments ...
Страница 171: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 171 Using the Data Sequence Editor ...
Страница 181: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 181 Running the Test ...
Страница 186: ...Running the Test How to Start Stop the Test 186 HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 ...
Страница 187: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 187 Viewing Generated and Captured Data ...
Страница 199: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 199 Using Auxiliary Functions ...
Страница 215: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 215 How Do I ...
Страница 240: ...Index 240 HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 ...