How to Set the Clock Characteristics
Setting Global System Parameters
HP 81200 Data Generator/Analyzer Platform User Guide, Revision 2.1
89
3
If desired, set a global
Delay Offset
.
A global delay offset enables you to specify negative time offsets for
individual signals. Such signals appear in advance of the regular clock
pulse.
4
Check the
Blocklength Granularity
and
Frequency Multiplier Range.
The blocklength granularity has an impact on the available memory
resources for generating or capturing data. The default setting of the
blocklength granularity is 4.
The Frequency Multiplier Range (FMR) determines the available
multiplication factors that can be used for multiplying the entered
system clock frequency. The blocklength granularity has an impact on
the available memory resources for generating or capturing data.
Depending on the desired clock rate you can choose a lower or higher
blocklength granularity.
For details refer to
“FMR and Blocklength Granularity” on page 31
Table 2
Clock Rates, FMR, and Blocklength Granularity
Block Length
Granularity
Frequency Multiplier
Range
Memory Depth System Clock Rates
1 bit (=1)
1, 2, 4, 8, 16
64 kbit
41.67 MHz
2 bits (=2)
1/2, 1, 2, 4, 8
128 kbit
83.83 MHz
4 bits (=4)
1/4, 1/2, 1, 2, 4
256 kbit
166.67 MHz
8 bits (=8)
1/8, 1/4, 1/2, 1, 2
512 kbit
333.33 MHz
16 bits (=16)
1/16, 1/8, 1/4, 1/2, 1
1 Mbit
660 MHz
Содержание 81200
Страница 1: ...Revision 2 1 HP 8 1 200 D a t a G e n e r a t o r A n a l y z e r P l a t f o r m User Guide ...
Страница 9: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 9 What s New in This Release ...
Страница 15: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 15 Introduction to the System ...
Страница 49: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 49 Test Development Overview ...
Страница 57: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 57 Structure of the User Interface ...
Страница 83: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 83 Setting Global System Parameters ...
Страница 93: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 93 Connecting the DUT ...
Страница 105: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 105 Setting Up Ports and Channels ...
Страница 127: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 127 Choosing the Kind of Measurement ...
Страница 155: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 155 Creating and Editing Segments ...
Страница 171: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 171 Using the Data Sequence Editor ...
Страница 181: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 181 Running the Test ...
Страница 186: ...Running the Test How to Start Stop the Test 186 HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 ...
Страница 187: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 187 Viewing Generated and Captured Data ...
Страница 199: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 199 Using Auxiliary Functions ...
Страница 215: ...HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 215 How Do I ...
Страница 240: ...Index 240 HP 81200 Data Generator Analyzer Platform User Guide Revision 2 1 ...