![HP 70000 series Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/hp/70000-series/70000-series_user-manual_161488045.webp)
HP-MSIB
if
the
HP-MSIB
indicator
(called
I/O
CHECK
on
some
models)
turns
on,
inspect
all
module
interconnections
for
tightness
and
then
cycle
power
.
If
the
HP-MSIB
indicator
remains
on,
consult
the
HP
70000
Modular
Spectrum
Analyzer
Installation
and
V
erication
Manual.
Status
Denotes
the
active
or
error
state
.
The
active
(A
CT)
indicator
lights
whenever
analyzer
functions
are
accessed
by
pressing
the
4
USER
5
or
4
MENU
5
key
.
The
error
(ERR)
indicator
lights
when
the
analyzer
has
sensed
an
error
in
that
module
.
T
o
learn
the
nature
of
the
error
and
its
source
,
press
4
DISPLA
Y
5 ,
4
REPORT
ERRORS
5 ,
which
lists
the
error
code
and
the
module
where
the
error
originated.
(See
Appendix
C
for
error
code
denitions
.)
Press
4
MENU
5
to
return
to
the
normal
instrument
display
.
The
display
also
has
active
and
error
indicators
,
an
A
and
E
that
appear
in
the
upper-left
corner
(or
lower-right
corner
on
some
models)
of
the
display
.
The
active
indicator
lights
when
the
4
DISPLA
Y
5
key
is
pressed.
The
error
indicator
lights
when
an
error
is
sensed
by
the
display
module
.
HP-IB
describes
the
remote-control
status
of
the
analyzer
.
When
power
is
applied,
the
analyzer
is
in
local
control
and
the
indicators
are
o.
If
the
analyzer
is
addressed
by
a
computer
,
the
remote
indicator
lights
and
the
listen,
talk,
or
service-request
indicator
lights
depending
on
the
computer
instructions
.
The
listen
indicator
lights
when
the
analyzer
has
received
instructions
or
data
from
the
computer
.
The
talk
indicator
lights
when
the
analyzer
has
sent
data
or
instructions
to
the
computer
.
The
service-request
indicator
lights
when
the
analyzer
has
requested
computer
service
.
Instrument
state
describes
the
instrument
operating
state
.
The
MEASURE
indicator
lights
as
the
analyzer
sweeps
each
frequency
band
and
blanks
during
retrace
and
between
frequency
bands
.
The
SELF
TEST
indicator
lights
whenever
the
analyzer
is
testing
itself.
The
LOOP
UNLOCK
indicators
usually
light
when
a
hardware
failure
occurs
.
If
any
of
these
indicators
are
lit,
check
all
module
interconnections
for
tightness
,
then
cycle
power
.
If
the
indicators
remains
lit,
refer
to
the
troubleshooting
instructions
in
the
HP
70000
Modular
Spectrum
Analyzer
Installation
and
V
erication
Manual.
1-22
Overview
Содержание 70000 series
Страница 42: ...Auxiliary Measurement Indicators Figure 1 8 Auxiliary Measurement Indicators Overview 1 19 ...
Страница 67: ......
Страница 95: ......
Страница 346: ...Figure A 2 Simpli ed Lightwave Signal Analyzer Block Diagram Theory of Operation A 3 ...
Страница 366: ...Figure B 6 HP 70620A B Preampli er and HP 70621A Preampli er Front View Input and Output Ports B 11 ...
Страница 395: ......
Страница 447: ......