System
Diagnostics
Utilities
A
copy
of
the
System
Diagnostics
utility
program
is
shipped
with
this
manual
on
3-1/2
inch
disks
.
These
utility
programs
run
on
HP
9000
Series
200/300
controller
that
have
HP
B
ASIC
2.0
with
extensions
2.1,
or
equivalent,
loaded.
Each
disk
contains
the
following
System
Diagnostics
utilities
.
SA
VE
ST
A
TE
saves
both
the
instrument
state
and
the
contents
of
the
spectrum
analyzer
RAM
on
disk.
RSTR
ST
A
TE
(Restore
State)
restores
the
RAM
contents
and
the
instrument
state
to
the
spectrum
analyzer
.
DOWN
DIA
G
(Download
Diagnostics)
downloads
diagnostics
into
the
local
oscillator
RAM
and
displays
the
N
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SYSTEM
DIAG
softkey
in
the
user-softkey
menu.
Pressing
this
softkey
initiates
the
program.
The
original
instrument
state
is
not
restored
after
execution
of
the
program.
REM
DIA
G
(Remote
Diagnostics)
saves
both
the
instrument
state
and
RAM
contents
on
disk,
runs
System
Diagnostics
,
then
reports
any
errors
to
the
computer
screen.
Finally
,
it
restores
the
instrument
state
and
RAM
contents
.
Running
the
System
Diagnostics
Utilities
Use
the
following
procedure
to
run
any
of
the
utilities
on
an
HP
9000
Series
200/300
controller
.
1.
Load
B
ASIC
2.0
with
extensions
2.1,
or
equivalent.
2.
Use
an
HP-IB
cable
to
connect
the
HP-IB
of
the
computer
to
the
spectrum
analyzer
.
This
cable
must
connect
directly
to
the
HP
70004A
color
display
or
HP
70001A
mainframe
that
contains
the
master
(HP
70900B
local
oscillator
source).
3.
Insert
the
disk
labeled
System
Diagnostics
Software
(Disk
1
of
1)
into
the
default
drive
of
the
computer
.
4.
Type
the
command
LOAD .
F
ollow
with
a
space
and
the
name
of
the
utility
in
quotes
(for
example
,
LOAD
"SAVE_STATE" ).
5.
Press
EXECUTE .
Note
Only
the
REM
DIA
G
utility
allows
the
System
Diagnostics
program
to
be
run
repeatedly
.
T
o
run
the
test
again,
press
RUN
and
follow
the
instructions
on
the
computer
screen.
6.
Press
RUN
and
follow
the
instructions
on
the
computer
screen.
The
softkeys
that
are
normally
displayed
after
pressing
4
USER
5
or
4
MENU
5
are
not
visible
while
the
program
is
running.
Some
keys
return
when
the
program
is
nished
others
require
\LOCAL"
commands
.
5-20
T
roubleshooting
Содержание 70000 series
Страница 42: ...Auxiliary Measurement Indicators Figure 1 8 Auxiliary Measurement Indicators Overview 1 19 ...
Страница 67: ......
Страница 95: ......
Страница 346: ...Figure A 2 Simpli ed Lightwave Signal Analyzer Block Diagram Theory of Operation A 3 ...
Страница 366: ...Figure B 6 HP 70620A B Preampli er and HP 70621A Preampli er Front View Input and Output Ports B 11 ...
Страница 395: ......
Страница 447: ......