chromatic
dispersion
Chromatic
dispersion
is
pulse
broadening
due
to
the
dierent
velocities
of
dierent
colors
contained
in
the
spectrum
of
the
source;
the
pulse
broadening
depends
directly
on
the
spectral
width
of
the
source
.
Chromatic
dispersion
is
basically
a
material
property;
it
also
contributes
to
the
reduction
of
the
bandwidth
of
the
multimode
ber
.
Chromatic
dispersion
cannot
be
measured
directly;
instead,
multimode
dispersion
adds
quadratically
to
the
measurement
result.
clear-write
mode
The
specied
trace
(A,
B
,
or
C)
is
swept
and
updated
each
time
the
trigger
conditions
are
met.
column
See
address
map.
command
Code
that
controls
operation
of
modular
measurement
instruments
.
The
local-oscillator
module
responds
to
programming
commands
that
are
described
in
this
manual.
The
display
responds
to
a
dierent
set
of
programming
commands
,
which
are
described
in
documentation
for
the
HP
70004A
color
display
,
HP
70205A
graphics
display
,
and
HP
70206A
system
graphics
display
.
See
function.
System-level
commands
form
the
operating
system
for
computer-controlled
measurements
.
Examples
of
system-level
commands
are
CLEAR
or
OUTPUT
in
the
HP
B
ASIC
language
.
compatible
functions
See
function.
continuous
sweep
mode
A
ctive
traces
are
swept
continuously
.
The
sweep
begins
each
time
the
trigger
conditions
are
met.
correction
factors
Osets
applied
to
spectrum-analyzer
circuitry
to
compensate
for
circuit
errors
when
using
a
particular
input
port.
The
calibration
functions
can
apply
the
osets
individually
or
all
at
once
to
the
following
parts
of
the
spectrum
analyzer:
logarithmic
ampliers
resolution
bandwidths
front-end
circuitry
attenuator
step-gain
ampliers
data
line
Area
at
bottom
of
screen
for
data
entry
,
such
as
for
the
NNNNNNNNNNNNNNNNNNNNNNN
COMMAND
and
NNNNNNNNNNNNNNNNN
debug
functions
.
debug
mode
Mode
activated
with
DEBUG
programming
command
or
front-panel
NNNNNNNNNNNNNNNNN
debug
keys
,
where
spectrum-analyzer
commands
are
displayed
in
the
data
line
as
each
command
is
executed.
When
a
faulty
command
is
encountered,
operation
of
a
computer
program
or
user-dened
function
stops
.
The
last
characters
in
the
data
line
(at
the
right
end)
form
the
faulty
command.
delta
marker
Second
marker
that
is
positioned
relative
to
the
position
of
the
normal
marker
.
When
the
delta
marker
is
displayed,
the
marker
readouts
give
the
amplitude
and
frequency
dierence
between
the
delta
and
normal
(reference)
markers
.
Glossary-4
Содержание 70000 series
Страница 42: ...Auxiliary Measurement Indicators Figure 1 8 Auxiliary Measurement Indicators Overview 1 19 ...
Страница 67: ......
Страница 95: ......
Страница 346: ...Figure A 2 Simpli ed Lightwave Signal Analyzer Block Diagram Theory of Operation A 3 ...
Страница 366: ...Figure B 6 HP 70620A B Preampli er and HP 70621A Preampli er Front View Input and Output Ports B 11 ...
Страница 395: ......
Страница 447: ......