Errors
0001
{
0999
0070
RF
Preamplifier
Cause:
The
HP
70621A
preamplier
or
HP
70620B
preamplier
Option
001
RF
preamplier
has
failed
its
diagnostic
test.
This
error
will
occur
if
the
signal
level
gain
through
the
RF
preamplier
path
at
300
MHz
is
less
than
or
equal
to
0
dB.
Cure:
The
most
likely
failure
is
the
RF
preamplier
microcircuit.
Troubleshoot
and
repair
this
component
and
its
power
supply
.
6-12