Invalid address: <address> (Error 310)
You specified an invalid address value as an argument to a command (other than an
analyzer command). For example, you may have specified digits that don’t
correspond to the base specified, or you forgot to precede a hexadecimal letter digit
with a number (even zero (0)).
Action: Reenter the command and the address specification. Use online help by
typing help --EXPR-- and help --SYMB--. See the <ADDRESS> and the
<EXPRESSION> syntax pages in this manual for information on address
specifications.
Invalid address range: <address_range> (Error 311)
Cause: You specified an invalid address range as an argument to a command (other
than an analyzer command). For example, you may have specified digits that don’t
correspond to the base specified, or you forgot to precede a hexadecimal letter digit
with a number, or the upper boundary of the range you specified is less than the
lower boundary.
Action: Reenter the command and the address specification. Use online help by
typing help --EXPR-- and help --SYMB--. See the <ADDRESS> and
<EXPRESSION> syntax pages in this manual for information on address
specifications. Also, make sure that the upper boundary specification is greater than
the lower boundary specification (the lower boundary must always precede the
upper boundary on the command line).
Invalid answer in ascii config file; configuration aborted
Cause: A configuration file (filename.EA) being loaded into the emulator has at
least one invalid answer to a configuration question.
Action: Display the emulator error log to see which answer(s) were invalid. Edit
the configuration file and correct the invalid answer(s) or create a new
configuration file by modifying the emulator configuration and storing it.
Invalid attribute for memory type : <attribute> (Error 140)
Cause: You tried to specify a memory attribute for target memory. Attibutes are
valid for emulation memory only (memory types eram and erom), not for target
memory or guarded memory.
Action: Reenter your specification and use attributes only when specifying
emulation memory space.
Chapter 12: Emulator Error Messages
Invalid address: <address> (Error 310)
419
Содержание 64780A
Страница 1: ...Graphical User Interface User s Guide MC68360 68EN360 Emulator Analyzer HP 64780A ...
Страница 20: ...xx ...
Страница 21: ...Part 1 Quick Start Guide 1 ...
Страница 23: ...1 Getting Started 3 ...
Страница 45: ...Part 2 Using The Emulator 25 ...
Страница 47: ...2 Plugging into a Target System 27 ...
Страница 55: ...Chapter 2 Plugging into a Target System Plugging into the Motorola QUADS Target System 35 ...
Страница 59: ...3 Starting and Exiting HP 64700 Interfaces 39 ...
Страница 69: ...4 Entering Commands 49 ...
Страница 103: ...5 Configuring the Emulator 83 ...
Страница 122: ...102 ...
Страница 123: ...6 Using the Emulator 103 ...
Страница 193: ...7 Using the Emulation Bus Analyzer How to record program execution in real time 173 ...
Страница 249: ...8 Making Software Performance Measurements 229 ...
Страница 279: ...9 Making Coordinated Measurements 259 ...
Страница 295: ...Part 3 Reference 275 ...
Страница 297: ...10 Setting X Resources 277 ...
Страница 312: ...292 ...
Страница 313: ...11 Emulator Analyzer Interface Commands 293 ...
Страница 391: ...set Chapter 11 Emulator Analyzer Interface Commands set 371 ...
Страница 405: ... SYMB Chapter 11 Emulator Analyzer Interface Commands SYMB 385 ...
Страница 422: ...402 ...
Страница 460: ...440 ...
Страница 461: ...Part 4 Concept Guide 441 ...
Страница 463: ...13 Concepts of the EMSIM and EMRAM 443 ...
Страница 471: ...Part 5 Installation and Service Guide 451 ...
Страница 473: ...14 Installation 453 ...
Страница 491: ...Chapter 14 Installation Verifying the Installation 471 ...
Страница 493: ...15 Installing Updating Emulator Firmware 473 ...
Страница 500: ...480 ...
Страница 516: ...496 ...
Страница 540: ...520 ...